Dwyer Instruments RHP-2D10 | 6CTN3 | Relative Temperature & Humidity Transmitter / Transmitter | Raptor Supplies United Kingdom
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.
Sign In

Flat Shipping at £19.99 + VAT

DWYER INSTRUMENTS RHP-2D10 Relative Temperature & Humidity Transmitter / Transmitter | AE8EVE 6CTN3

DWYER INSTRUMENTS RHP-2D10 Relative Temperature & Humidity Transmitter / Transmitter

Item: AE8EVE Model: RHP-2D10Cross Ref: 6CTN3
In Stock

Get it by Tuesday, Jan 7

£19.99 Flat Shipping + VAT £19.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates

£191.44 /unit (Inc. VAT)
Trade Prices Available
Add To Cart
Request a Quote

Payment Methods

Delivery Partners

How NET30 Works

Step 1 Add the items into your cart or submit a Purchase order

Step 2 Checkout, select NET30 payment (provide company registration and VAT number)

Step 3 Delivery via TNT or Royal Mail and receive invoice for payment in 30-days

Step 4 Make payment via BACS to our factoring partner,

Product Specifications:

ItemHumidity Transmitter
Calibration CertificateNIST
Connection Size1/2"
Connection TypeNPS
Electrical ConnectionScrew Terminal
Enclosure MaterialPolycarbonate
Enclosure RatingIP 66
Gap Temp. Sensor Accuracy-/+ 0.9 Deg. F @ 77 Deg. F
Gap Temp. Sensor Range-20 Deg. to 140 Deg. F
Humidity Accuracy-/+ 2%
Hysteresis-/+ 1%
Mounting TypeDuct
Output Current4 to 20 mA
Power Required10 to 35V DC
Probe Dia.27/50"
Probe Length9"
Relative Humidity Range0 to 100% RH
Repeatability-/+ 0.1% Typical
Response Time15 sec.
Rh SensorCapacitance Polymer
Rtd Temp. Sensor Accuracy-/+ 0.54 Deg. F @ 32 Deg. F
Rtd Temp. Sensor Range-40 Deg. to 140 Deg. F
Sensor TypeRTD or Thermistor
Thermistor Temp. Sensor Accuracy-/+ 0.36 Deg. F @ 77 Deg. F
Thermistor Temp. Sensor Range-40 Deg. to 140 Deg. F

Shipping Info:

Ship weight (kg) 0.43
Ship height (cm)35.56
Ship length (cm)11.43
Ship width (cm)14.99
HS code9025801000
Country of OriginUS

Product Details:

Dwyer Instruments RHP-2D10 transmitter / transducer is designed for outdoor temperature & relative humidity reference, air economisers and pool room humidity monitoring. It offers high accuracy, long-term stability, flexibility and reliable operation.

Working Mechanism:

  • The capacitance or resistance of air samples is used to measure the temperature and humidity of the environment.
  • The sensor measures the moisture quantity in the air using capacitive technology. This type of measurement depends on an electrical field created between two electrical conductors and a non-conductive polymer sheet placed in between them.
  • As moisture from the air gathers on the film, the voltage levels between the two plates vary.
  • After accounting for the air temperature, this alteration is then transformed into a computerised measurement of the relative humidity of the air.
  • Resistive humidity sensors monitor humidity by passing ionised salts between two electrodes.
  • The salt ions gauge the electrical resistance of atoms. The resistance of the electrodes varies along with the humidity levels.
  • A dual sensor system is used by a thermal sensor to monitor humidity.
  • While one thermal sensor is free to measure ambient air, the other is enclosed in a layer of dry nitrogen.
  • The difference between the two measurement results determines how much moisture is in the air.

Features:

  • Dwyer Instruments RHP-2D10 relative temperature & humidity transducer / transmitter has NEMA 4X rated enclosure to protect against corrosion, splashing water and windblown dust or rain.
  • It features polymer construction to resist condensation, high humidity, fog and contaminants.
  • The unique design combines the voltage or current humidity transmitter output with a passive temperature thermistor or RTD output sensor.
  • The Series RHP's cutting-edge sensor technology allows it to recover from 100 percent saturation and is completely calibration-free.
  • Quick service and a decrease in full unit inventory are made possible by the field replaceable sensor and detachable filter of the unit.
  • The metal mounting flange on this duct mount model shortens the time it takes to attach the transmitter to the duct.
  • It can be ordered with just one current or voltage output for humidity or it can be factory customised also to have a voltage output, a passive RTD output or a temperature output using a thermistor. Without additional calibration, the RTD and thermistor outputs can be used interchangeably in the field.

Compatible Accessories:

  • Dwyer A-449 Remote Displays: They are two-line alphanumeric LCD screens engineered for the user to easily read the temperature and humidity at once.

Standards and Approvals:

  • CE
  • RoHS

Frequently Asked Questions:

Q. How to install this relative humidity transducer?

A.

  • Drill a hole in the duct at the desired location.
  • Through the opening, insert the transmitter probe so that the mounting flange is flush with the duct.
  • The mounting flange should be fastened to the duct with three 1/2-inch pan head sheet metal screws.
  • Avoid over tightening.
  • To access the wire terminals, remove the top screw cover.

Q. What are the important points to consider before installing this transmitter?

A.

  • Before installation, disconnect the power source to avoid electrical shock and equipment damage.
  • Precautions for electrostatic discharge should be used, such as wrist straps during wiring and installation to guard against equipment damage.
  • Avoid areas where there is an excess of moisture, vibration or corrosive vapours.
  • Do not exceed the electrical ratings.
  • The relative humidity measurement of the transmitter should not be impacted by fans, corners, heating and cooling coils or other equipment.
  • Additionally, it needs to be installed where it will receive enough airflow to function properly.
  • To keep moisture out, the transmitter should be positioned so that the conduit connection faces downward.

Q. How to perform field sensor replacements?

A.

  • Remove the plastic cover or sintered filter.
  • Remove and discard old sensors.
  • Replace the sensor, ensuring that all six pins mate correctly with the socket and that the boards are correctly aligned.
  • Replace the plastic cover or sintered filter.

Documentation:

Datasheet

Product Variants

ProductModelAccuracyItemMountingMounting TypeOutput VoltagePower RequiredProbe Dia.Probe LengthPrice
DWYER INSTRUMENTS RHP-3O10 Humidity Transducer, 10 To 35vdc | AE8ETK 6CTH1
RHP-3O10-3% to +3%Humidity TransducerSurfaceSurface-10.0V DC - 35.0V DC1 3/25"3"£175.74
DWYER INSTRUMENTS RHP-3O11 Humidity/temperature Transducer, -20 To 140 Deg F | AE8ETL 6CTH2
RHP-3O11-3% to +3%Humidity/Temp TransducerSurfaceSurface-10.0V DC - 35.0V DC1 3/25"3"£195.00
DWYER INSTRUMENTS RHP-3O20 Humidity Transducer, 15 To 35vdc | AE8ETM 6CTH3
RHP-3O20-3% to +3%Humidity TransducerSurfaceSurface0.0V DC - 10.0V DC15 to 35V DC, 15 to 29V AC1 3/25"3"£192.61
DWYER INSTRUMENTS RHP-3O22 Humidity/temperature Transducer, -20 To 140 Deg F | AE8ETN 6CTH4
RHP-3O22-3% to +3%Humidity/Temp TransducerSurfaceSurface0.0V DC - 10.0V DC15 to 35V DC, 15 to 29V AC1 3/25"3"£189.97
DWYER INSTRUMENTS RHP-3O1A Humidity/temperature Transducer, -40 To 140 Deg F | AE8ETP 6CTH5
RHP-3O1A-3% to +3%Humidity/Temp TransducerSurfaceSurface-10.0V DC - 35.0V DC1 3/25"3"£186.07
DWYER INSTRUMENTS RHP-3O1B Humidity/temperature Transducer, -40 To 140 Deg F | AE8ETQ 6CTH6
RHP-3O1B-3% to +3%Humidity/Temp TransducerSurfaceSurface-10.0V DC - 35.0V DC1 3/25"3"£203.74
DWYER INSTRUMENTS RHP-3O1D Humidity/temperature Transducer, -40 To 140 Deg F | AE8ETR 6CTH7
RHP-3O1D-3% to +3%Humidity/Temp TransducerSurfaceSurface-10.0V DC - 35.0V DC1 3/25"3"£182.84

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

DWYER INSTRUMENTS RHP-2D10 Relative Temperature & Humidity Transmitter / Transmitter
£191.44 /unit (Inc. VAT)