Dwyer Instruments A-417A | 23Z321 | Static Pressure Pickup, Wall Plate, Stainless Steel | Raptor Supplies United Kingdom
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.
Sign In

Flat Shipping at £19.99 + VAT

DWYER INSTRUMENTS A-417A Static Pressure Pickup, Wall Plate, Stainless Steel | AB7RJE 23Z321

DWYER INSTRUMENTS A-417A Static Pressure Pickup, Wall Plate, Stainless Steel

Item: AB7RJE Model: A-417ACross Ref: 23Z321
In Stock

Get it by Friday, Dec 27

£19.99 Flat Shipping + VAT £19.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates

£16.09 /unit (Inc. VAT)
Trade Prices Available
Add To Cart
Request a Quote

Payment Methods

Delivery Partners

How NET30 Works

Step 1 Add the items into your cart or submit a Purchase order

Step 2 Checkout, select NET30 payment (provide company registration and VAT number)

Step 3 Delivery via TNT or Royal Mail and receive invoice for payment in 30-days

Step 4 Make payment via BACS to our factoring partner,

Product Specifications:

ItemStatic Pressure Pickup Wall Plate
Connection Size1/8" to 3/16"
Fitting TypeBarbed
MaterialStainless Steel
Tube Inside Dia.1/8" to 3/16"

Shipping Info:

Ship weight (kg) 0.07
Ship height (cm)2.03
Ship length (cm)11.18
Ship width (cm)7.87
HS code9026906000
Country of OriginCN

Product Details:

Dwyer A-417A static pressure wall plate pickup is used in commercial and industrial buildings to monitor the performance and efficiency of ventilation systems. It is suitable for manometers, Magnehelic gauges, pressure switches and similar controllers.

Working Mechanism:

  • Static pressure pickup typically consists of a small opening or hole in a wall plate or duct that senses the air pressure. The pickup is connected to a pressure transducer or gauge, which converts the pressure into a readable value. The pickup measures the pressure difference between two points in the system, enabling the assessment of static pressure.

Features:

  • Dwyer A-417A static pressure wall plate pickup features a 60-micron filter to pick up or sense static pressure drop across air filters and cooling coils.
  • It has a foam gasket for sealing and features stainless steel construction for resisting corrosion on exposed surfaces and structural rigidity.
  • This static pressure wall plate pickup has barbed brass fitting to hold 1/8 to 3/16 inch Inner diameter tubing.
  • It is designed as a wall plate, allowing for easy installation and integration into the HVAC system.

Frequently Asked Questions:

Q. What is the importance of measuring static pressure in HVAC systems?

A. Measuring static pressure in HVAC systems is crucial for maintaining proper air circulation, assessing system efficiency and identifying potential issues such as clogged filters, duct leaks or imbalanced airflow. It helps ensure the optimal functioning of the system and can contribute to energy savings.

Q. How often should static pressure measurements be taken?

A. The frequency of static pressure measurements varies depending on factors such as the size of system, complexity and operating conditions.

Q. How to masure static pressure from this wall plate pickup?

A. The static pressure pickup typically consists of a small opening or hole in a wall plate, duct, or probe. This opening is designed to sense the pressure of the fluid or gas in the system. The pickup is connected to a pressure transducer or gauge, which converts the sensed pressure into a measurable value.

Q. What is the importance of measuring static pressure in HVAC systems?

A. Measuring static pressure in HVAC systems is crucial for maintaining proper air circulation, assessing system efficiency and identifying potential issues such as clogged filters, duct leaks or imbalanced airflow. It helps ensure the optimal functioning of the system and can contribute to energy savings.

Q. How often should static pressure measurements be taken?

A. The frequency of static pressure measurements varies depending on factors such as the size of system, complexity and operating conditions.

Q. How to masure static pressure from this wall plate pickup?

A. The static pressure pickup typically consists of a small opening or hole in a wall plate, duct, or probe. This opening is designed to sense the pressure of the fluid or gas in the system. The pickup is connected to a pressure transducer or gauge, which converts the sensed pressure into a measurable value.

Q. Does Raptor Supplies offer wall mounted static pressure pickup?

A. Yes, Raptor Supplies offers Dwyer A-418A static pressure pickup offering wall mounting for easy and secure installation.

Documentation:

Datasheet

Product Variants

ProductModelItemMaterialPrice
DWYER INSTRUMENTS A-418A Static Pressure Pickup Wall Mount, 1/8 to 3/16 Inch Connection | AB7RJF 23Z322
A-418AStatic Pressure Pickup Wall MountPlastic£21.00
DWYER INSTRUMENTS A-419A Static Pressure Pickup Ceiling Plate, 60 micron filter | AB7RJG 23Z323
A-419AStatic Pressure Pickup Ceiling PlateMetal£17.38
DWYER INSTRUMENTS A-420A Outside Air Static Pressure Pickup | AB7RJH 23Z324
A-420AStatic Pressure PickupBrass£36.23