Sign In
BALDOR / DODGE CCPX25166T Explosion Proof Severe Duty | CD6LDN

BALDOR / DODGE CCPX25166T Explosion Proof Severe Duty

Item: CD6LDN Model: CCPX25166T
Limited Availability

Get it by Monday, Apr 28

Trade Prices Available
Request a Quote

Payment

Delivery

How NET30 Works

Step 1 Add the items into your cart or submit a Purchase order

Step 2 Checkout, select NET30 payment (provide company registration and VAT number)

Step 3 Delivery via TNT or Royal Mail and receive invoice for payment in 30-days

Step 4 Make payment via BACS to our factoring partner,

Product Specifications:

Agency ApprovalsCSA EEVUL
Ambient Temperature40 °C
AMPS28.4/14.2//26.4/13.2
Auxillary BoxNo Auxillary Box
Auxillary Box Lead TerminationNone
Base IndicatorRigid
Bearing Grease TypePolyrex EM (-20F +300F)
BlowerNone
Break-Down Torque139 LB-FT
Break-Down Torque144 LB-FT
C HP FR60
C HP TO90
CC010A
CLF
Constant Torque Speed Range6
CT HZ FROM6
CT HZ TO60
Current @ Voltage28.400 A @ 230.0 V30.000 A @ 208.0 V26.400 A @ 190.0 V14.200 A @ 460.0 V13.200 A @ 380.0 V
DESA
Design CodeA
Drip CoverNo Drip Cover
Duty RatingCONT
Efficiency @ 100% Load91.0 %
Efficiency_0%0.0
Efficiency_100%91.6
Efficiency_125%91.2
Efficiency_150%90.3
Efficiency_25%84.4
Efficiency_50%90.2
Efficiency_75%91.6
Efficiency_S.F.0.0
Electrically Isolated BearingNot Electrically Isolated
EnclosureTEFC
Enclosure ModificationSevere Duty Features
Feedback DeviceNO FEEDBACK
Frame256TC
Frame MaterialCast Iron
Frequency50.00 Hz60.00 Hz
Full Load Torque0 LB-FT
Haz Area Class and GroupCLI GP C,D; CLII GP E,F,G
Haz Area DivisionDivision I
Haz Area Temp CodeT3C
Heater IndicatorNo Heater
High Voltage Full Load Amps13.2 a
HP10//7.5
HZ60//50
Insulation ClassF
INV.TYPEPWM
Inverter CodeInverter Duty
IP RatingIP55
KVA CodeJ
Lifting LugsStandard Lifting Lugs
Line Amps_0%7.15
Line Amps_100%14.20
Line Amps_125%17.24
Line Amps_150%20.55
Line Amps_25%8.00
Line Amps_50%9.39
Line Amps_75%11.57
Line Amps_S.F.0.00
Line-Line Res. @ 25° C0.676 Ohms A Ph / 0 Ohms B Ph
Line-Line Res. @ 25° C0.675 Ohms A Ph / 0 Ohms B Ph
Locked Bearing IndicatorLocked Bearing
Locked-Rotor Torque75 LB-FT
Locked-Rotor Torque79 LB-FT
MAG CUR14.4/7.2
Max Speed1800 rpm
Motor Lead TerminationFlying Leads
Motor Letter TypeThree Phase
Motor StandardsNEMA
Motor Type0960M
Mounting ArrangementF1
MX RPM1800
No-Load Current0 A
NOM.EFF.91
Number of Poles6
Output @ Frequency10.000 HP @ 60 HZ7.500 HP @ 50 HZ
Overall Length26.04 IN
PH3
Phase3
Power Factor72
Power Factor_0%5.0
Power Factor_100%72.0
Power Factor_125%74.0
Power Factor_150%76.0
Power Factor_25%35.0
Power Factor_50%55.0
Power Factor_75%66.0
Power Factor_S.F.0.0
Pull-Up Torque54.6 LB-FT
Pull-Up Torque57.51 LB-FT
Pulley Face CodeC-Face
RATING40C AMB-CONT
Rodent ScreenNone
RoHS StatusROHS NON-COMPLIANT
RPM1180//980
SER.F.1.00
Service Factor1.00
Shaft Diameter1.625 IN
Shaft Ground IndicatorNo Shaft Grounding
Shaft RotationReversible
SL HZ1
Speed1180 rpm
Speed (RPM)_0%1,199
Speed (RPM)_100%1,181
Speed (RPM)_125%1,175
Speed (RPM)_150%1,168
Speed (RPM)_25%1,196
Speed (RPM)_50%1,191
Speed (RPM)_75%1,186
Speed (RPM)_S.F.0
Speed CodeSingle Speed
Start ConfigurationDOL
Starting Current91.23 A
Starting Current93 A
Starting MethodDirect on line
Synchronous Speed @ Frequency1200 RPM @ 60 HZ
TEMP CODET3C
Temp. Rise @ Rated Load44° C
Temp. Rise @ Rated Load39° C
Temp. Rise @ S.F. Load47° C
Thermal Device - BearingNone
Thermal Device - WindingNormally Closed Thermostat
Vibration Sensor IndicatorNo Vibration Sensor
Voltage @ Frequency380.0 V @ 50 HZ230.0 V @ 60 HZ190.0 V @ 50 HZ460.0 V @ 60 HZ
VOLTS230/460//190/380
VT HZ FROM6
VT HZ TO60
Winding Thermal 1None
Winding Thermal 2None
WK24.82

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

BALDOR / DODGE CCPX25166T Explosion Proof Severe Duty