Dayton 6RJW6 | Gas Fired Duct Furnace, 150000 BtuH Heating Capacity Input, Aluminized Steel, Side | Raptor Supplies United Kingdom
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.
Sign In
DAYTON 6RJW6 Gas Fired Duct Furnace, 150000 BtuH Heating Capacity Input, Aluminized Steel, Side | AF2DHR

DAYTON 6RJW6 Gas Fired Duct Furnace, 150000 BtuH Heating Capacity Input, Aluminized Steel, Side

Item: AF2DHR Model: 6RJW6
In Stock

Get it by Friday, Jan 3

£2,738.89 /unit (Inc. VAT)
Trade Prices Available
Add To Cart
Request a Quote

Payment Methods

Delivery Partners

How NET30 Works

Step 1 Add the items into your cart or submit a Purchase order

Step 2 Checkout, select NET30 payment (provide company registration and VAT number)

Step 3 Delivery via TNT or Royal Mail and receive invoice for payment in 30-days

Step 4 Make payment via BACS to our factoring partner,

Product Specifications:

ItemIndoor Duct Furnace
Air Flow3704 cfm
Air Temp. Rise30 Deg. F
Btuh Input150,000
Btuh Output120,000
Burner Air Inlet Size5"
Cfm @ 65(f) Rise1500 cfm
Cfm @ 80(f) Rise1700 cfm
Combustion TypeOpen Combustion
Depth37"
FeaturesClamshell Style Heat Exchanger
Flue Dia.4"
Frequency60 Hz
Fuel TypeNatural Gas
Full Load Amps1.9A
Gas Connection1/2"
Gas Connection Size1/2"
Gas Connection TypeMale NPT
Gas TypeNG
Heat Exchanger Gauge20 ga.
Heating Capacity Input150,000 BtuH
Heating Capacity Output120,000 BtuH
Heating MethodFan Forced
Height37.75"
Hz60
Ignition SystemDirect Spark
Ignition TypeDirect Spark
Indoor Air Discharge Height19"
Indoor Air Discharge Width18 1/4"
Installation Height8 ft.
Max. Amps1.9A
Max. External Sp0.75" wc
Mounting Height8 ft.
Overall Depth37"
Overall Height37 3/4"
Overall Width20 5/8"
Primary Heat Exchanger MaterialAluminized Steel
Required Air Flow1389 cfm
Service Access LocationSide
Vent TypePower
Voltage115V AC
Warranty1 Year
Width20.62"

Shipping Info:

Ship weight (kg) 88.65
Ship height (cm)95.89
Ship length (cm)93.98
Ship width (cm)52.39
HS code8416200040
Country of OriginUS

Product Details:

Dayton 6RJW6 indoor duct furnace is ideal for efficient heating using natural gas. This furnace is utilised in commercial and industrial settings to provide reliable and controlled heating through duct systems. Its natural gas operation offers cost-effective energy, making it ideal for maintaining comfortable temperatures in large areas. This furnace features an MNPT connection type for a secure and leak-resistant connection to the natural gas supply. It has an open combustion type to allow for efficient and effective heating. This indoor duct furnace features a clamshell-style heat exchanger to enhance heating efficiency and performance. It utilised natural gas fuel for contributing to cost-effective & energy-efficient heating. This ETL-certified furnace incorporates a primary heat exchanger crafted from aluminised steel, ensuring reliable heat transfer and durability. This Dayton 6RJW6 furnace offers direct spark ignition type for providing efficient & reliable ignition for heating operation.

Working Mechanism:

  • The furnace ignites natural gas within a dedicated chamber to initiate the combustion process.
  • Through combustion, the furnace generates heat energy from the burning natural gas.
  • A heat exchanger then efficiently transfers the generated heat to the surrounding air.
  • A powerful blower fan propels the heated air through ductwork, evenly distributing warmth indoors.
  • The furnace integrates safety features like flame sensors and limit switches to ensure secure operation and prevent potential hazards.

Frequently Asked Questions:

Q. What is the heating capacity of this Dayton 6RJW6 furnace?

A. This furnace has a heating capacity input of 150000 BTUh and an output of 120000 BTUh.

Q. What safety features does the furnace include?

A. This furnace includes additional safety features such as a fan time delay, air flow prove switch and terminal block wiring for enhanced operational safety and control.

Q. What is the maximum external static pressure that the furnace can handle?

A. This furnace can handle a maximum external static pressure of 0.75 inch WC.

Product Variants

ProductModelDepthHeightVoltagePrice
DAYTON 6RJV2 Indoor Duct Furnace 37 Inch D 3704 Cfm Ng | AF2DHB
6RJV237"37.75"120£2,773.99
DAYTON 6RJV9 Indoor Duct Furnace 37 Inch D Natural Gas 3704 Cfm | AF2DHJ
6RJV937"37.75"120£3,125.39
DAYTON 6RJX3 Indoor Duct Furnace 30 Degree F 3704 Cfm Ng | AF2DHZ
6RJX337"37.75"120£3,125.39
DAYTON 6RJY0 Indoor Duct Furnace 3704 Cfm Natural Gas 30 Degree F | AF2DJG
6RJY040"36"120£4,525.32
DAYTON 6RJY7 Indoor Duct Furnace Natural Gas 3704 Cfm 30 Degree F | AF2DJP
6RJY740"36"120£4,826.44

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

DAYTON 6RJW6 Gas Fired Duct Furnace, 150000 BtuH Heating Capacity Input, Aluminized Steel, Side
£2,738.89 /unit (Inc. VAT)