Item | Power Distribution Block |
Body Material | Nylon |
Design | Open |
For Conductor Material | Aluminum, Copper |
For Line Aluminum Wire Size - Minimum | 14 AWG |
For Line Copper Wire Size - Minimum | 14 AWG |
For Load Aluminum Wire Size - Maximum | 2 AWG |
For Load Aluminum Wire Size - Minimum | 14 AWG |
For Load Copper Wire Size - Min. | 14 AWG |
For Maximum Line Wire Size | 2/0 AWG |
For Maximum Load Wire Size | 2 AWG |
For Min. Line Wire Size | 14 AWG |
For Min. Load Wire Size | 14 AWG |
Housing Color | Natural |
Line Connections/pole | 1 |
Line Side Connection Type | Lug |
Line Side Stud Size | Not Applicable |
Load Connections/pole | 6 |
Load Side Connection Type | Lug |
Load Side Stud Size | Not Applicable |
Max. Amps | 175A |
Max. Operating Temp. | 194°F |
Max. Voltage | 600V AC/DC |
Maximum Current | 175A |
Maximum Current - Copper Conductor | 175A |
Number Of Circuits | 1 |
Number Of Poles | 1 |
Overall Depth | 3 22/25" |
Overall Length | 4.83" |
Overall Width | 2 12/25" |
Primary Connections/pole | 1 |
Rohs Compliant | Yes |
Secondary Connection/pole | 6 |
Special Features | Provided Capability To Create As Many Poles As Required, Up To 30 Tap Conductor Accommodated |
Terminal Material | Aluminum |
Ul 94 Flammability Rating | V-0 |
Approvals | AL9CU, cULus |
Composition | Polyamide |
Family Series | Burndy Power Distribution Blocks |
Flammability Rating | V-0 |
For Conductor Material | Aluminum; Copper |
For Conductor Material | Aluminum, Copper |
For Line Aluminum Wire Size - Maximum | 2/0 AWG |
For Line Aluminum Wire Size - Minimum | 14 AWG |
For Line Copper Wire Size - Maximum | 2/0 AWG |
For Line Copper Wire Size - Minimum | 14 AWG |
For Load Aluminum Wire Size - Maximum | 2 AWG |
For Load Aluminum Wire Size - Minimum | 14 AWG |
For Load Copper Wire Size - Maximum | 2 AWG |
For Load Copper Wire Size - Minimum | 14 AWG |
For Maximum Line Wire Size | 2/0 AWG |
For Maximum Load Wire Size | 2 AWG |
For Minimum Line Wire Size | 14 AWG |
For Minimum Load Wire Size | 14 AWG |
Housing Color | Natural |
Housing Material | Nylon |
Includes Cover | No |
Input Wire Range | 14-2/0 AWG |
Line Connections/Pole | 1 |
Line Side Connection Type | Lug |
Line Side Stud Size | Not Applicable |
Line Side Wire Size Range | 14 AWG - 2/0 AWG |
Line/Load Connection | Box Lug |
Load Connections/Pole | 6 |
Load Side Connection Type | Lug |
Load Side Stud Size | Not Applicable |
Max. Amps | 175 A |
Maximum Current | 175 A |
Maximum Current - Aluminum Conductor | 175 A |
Maximum Current - Copper Conductor | 175 A |
Maximum Operating Temperature | 194 Degrees F |
Maximum Operating Temperature | 194 °F |
Maximum Voltage | 600 V AC/DC |
Mounting Type | DIN Rail/Panel Mount |
Mounting Type | DIN-Rail; Surface Mount |
Number of Circuits | 1 |
Number of Inputs per Pole | 1 |
Number of Outputs per Pole | 6 |
Number of Poles | Not Applicable |
Number of Poles | 1 |
Output Wire Range | 12-2 AWG |
Overall Depth | 3.88 in |
Overall Length | 4.83 in |
Overall Width | 2.48 in |
Power Distribution Block Design | Open |
Primary Connections/Pole | 1 |
Primary Wire Range | 14 to 2/0 AWG |
Primary Wire Range (AWG) | 14 to 2/0 AWG |
RoHS Compliant | Yes |
Secondary Connection/Pole | 6 |
Secondary Wire Range | 14 to 2 AWG |
Secondary Wire Range (AWG) | 14 to 2 AWG |
Special Features | Provided Capability to Create as Many Poles as Required; Up to 30 Tap Conductor Accommodated |
Special Features | Provided Capability to Create as Many Poles as Required, Up to 30 Tap Conductor Accommodated |
Standards | cULus Certified |
Terminal Material | Aluminum |
Terminal Material | Aluminum; Copper |
UL 94 Flammability Rating | V-0 |
UL Compliance | UL1953 |
Voltage Rating | 1000V AC/DC |
Voltage Rating (AC) | 600 VAC |