Sign In

SPARTAN SCIENTIFIC 6200 Series, Solenoid Valve

Spartan Scientific 6200 Series solenoid valves are 2 / 3-way positioning valves used to control the flow of fluids in industrial automation, HVAC and irrigation systems.

Filter
StyleModelCoefficient Of VolumeOrifice Dia.Pipe SizeSeal MaterialVoltageWattsPrice
A
6200-B60-AAB2B
0.525/32"1/4"Buna N12 VDC10£63.83
A
6200-B60-AAB7B
0.525/32"1/4"Buna N120 VAC8£61.73
A
6200-B60-AAC2B
0.525/32"3/8"Buna N12 VDC10£62.75
A
6200-E60-AAB6B
0.525/32"1/4"EPDM24 VAC8£63.83
A
6200-E60-AAB3B
0.525/32"1/4"EPDM24 VDC10£64.74
A
6200-E60-AAB7B
0.525/32"1/4"EPDM120 VAC8£63.83
A
6200-B60-AAB3B
0.525/32"1/4"Buna N24 VDC10£63.52
A
6200-B60-AAB6B
0.525/32"1/4"Buna N24 VAC8£62.18
A
6200-E60-AAC3B
0.525/32"3/8"EPDM24 VDC10£63.83
A
6200-B60-AAC6B
0.525/32"3/8"Buna N24 VAC8£62.95
A
6200-B60-AAC7B
0.525/32"3/8"Buna N120 VAC8£61.73
A
6200-E60-AAB2B
0.525/32"1/4"EPDM12 VDC10£63.52
A
6200-E60-AAC2B
0.525/32"3/8"EPDM12 VDC10£63.83
A
6200-E60-AAC7B
0.525/32"3/8"EPDM120 VAC8£63.52
A
6200-E60-AAC6B
0.525/32"3/8"EPDM24 VAC8£62.18
A
6200-B60-AAC3B
0.525/32"3/8"Buna N24 VDC10£63.20
A
6200-B70-AAB6B
0.6113/64"1/4"Buna N24 VAC8£63.83
A
6200-E70-AAB7B
0.6113/64"1/4"EPDM120 VAC8£64.42
A
6200-E70-AAB6B
0.6113/64"1/4"EPDM24 VAC8£63.83
A
6200-E70-AAB2B
0.6113/64"1/4"EPDM12 VDC10£62.75
A
6200-B70-AAC6B
0.6113/64"3/8"Buna N24 VAC8£63.83
A
6200-E70-AAC2B
0.6113/64"3/8"EPDM12 VDC10£63.83
A
6200-B70-AAC7B
0.6113/64"3/8"Buna N120 VAC8£63.83
A
6200-B70-AAB3B
0.6113/64"1/4"Buna N24 VDC10£62.29
A
6200-E70-AAB3B
0.6113/64"1/4"EPDM24 VDC10£63.20
A
6200-B70-AAB7B
0.6113/64"1/4"Buna N120 VAC8£63.83
A
6200-E70-AAC3B
0.6113/64"3/8"EPDM24 VDC10£63.83
A
6200-E70-AAC7B
0.6113/64"3/8"EPDM120 VAC8£63.83
A
6200-E70-AAC6B
0.6113/64"3/8"EPDM24 VAC8£60.92
A
6200-B70-AAC3B
0.6113/64"3/8"Buna N24 VDC10£63.20
A
6200-B70-AAC2B
0.6113/64"3/8"Buna N12 VDC10£63.52
A
6200-B70-AAB2B
0.6113/64"1/4"Buna N12 VDC10£62.07

Working Mechanism

  • Solenoid valve consists of a coil, plunger, valve seat, and fluid passage.
  • In the de-energised state, the spring-loaded plunger remains against the valve seat, blocking fluid flow.
  • When the coil is charged, a magnetic field is generated, attracting the plunger and causing it to move away from the valve seat.
  • This movement opens the passage, allowing fluid to flow as long as the coil remains energised.
  • When the coil is de-energised, the spring force returns the plunger to its closed position, stopping fluid flow.

Features

  • These direct-acting valves feature glass-filled nylon construction for improved tensile strength and stiffness.
  • They have NEMA-rated coil enclosures for protection against water and dust.
  • These normally open / closed solenoid valves offer Buna-N / EPDM seals to ensure leak-proof connection.
  • They come with Class F coil insulation for improved electrical insulation and coil life.
  • These valves can withstand pressures ranging from 0 to 250 psi.

Standards and Approvals

  • CE

Frequently Asked Questions

What are the factors to consider when selecting a solenoid valve?

Major factors include the required flow rate and pressure, the type of fluid or gas being controlled, temperature, humidity, voltage and power consumption.

What is the response time of these solenoid valves?

They have a response time of 16 to 40 milliseconds (complete cycle).

We are here to help!

Looking for a part not listed here?