FRIEDRICH Hazardgard Series Non Atex Hazardous Location Air Conditioners

Friedrich hazardous location air conditioners are used for cooling control rooms, laboratories and storage areas.

Filter
StyleModelCooling CapacityVoltageAmpsAmps@voltsEERDehumidificationRefrigerant TypePrice
A
SH15M30A
15700/15700 BTUH,4.6/4.10kW230/2087.9/7.8250V-159.74 Pts/Hr.R-410A£7,162.15
A
SH20M50B
21000/19100 Btu/hr.220/ 240V11.6/ 10.3A250V @ 15A8.87 Pts/Hr.R-410A£8,601.82
A
SH20M30B
21000/ 21000 BTUH, 6.15kW230/ 208V10.5/9.4A250V-15A (230V)/ 250V-20A (208V)9.7/9.65.5 Pts/Hr.R-410A£8,312.07
A
SH24N30A
24000/24000 BTUH,6.8kW230/20811.8250V-209.7/8.58/7.5 Pts/Hr.R-410A£6,232.65

Hazardgard Series Non Atex Hazardous Location Air Conditioners

Friedrich hazardous location air conditioners are suitable for cooling spaces with flammable & volatile liquids / gases such as offshore oil rigs, petrochemical sites and munition plants. These air conditioners feature a vibration isolating design with steel inner wall blocks for diminishing noise levels and a hermetically sealed reciprocating compressor for tolerating high outdoor temperatures. Choose from a wide variety of these air conditioners, available in 50 & 60Hz options on Raptor Supplies.

Features

  • These air conditioners feature a vibration-isolating design with steel inner wall blocks for diminishing noise levels.
  • They have a hermetically sealed reciprocating compressor for tolerating high outdoor temperatures.
  • They have a powder coated, 22-gauge, G60 steel cabinet for resisting corrosion on exposed surfaces.
  • These ACs are equipped with solid-state relays and a sealed motor to prevent sparks when cooling potentially hazardous environments.
  • These Class 1, Division 2 units can be used where flammable liquids, gases and vapours are handled within an enclosed container or system..
  • They are available in 50 & 60Hz options.

Standards and Approvals

  • UL
  • ISA 12.12.01
  • NFPA 70
  • ANSI

Frequently Asked Questions

What is the advantage of a hermetically sealed compressor in the refrigerator?

It is compact in size and hence, needs less space. It produces less vibration and provides efficient lubrication as the compressor & motor operate in a sealed space with the lubricating oil.

What is the cooling capacity of Friedrich hazardous location air conditioners?

These ACs have a maximum cooling capacity of 24000 BTUh.