EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers | Raptor Supplies United Kingdom
Sign In

EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers

Eaton xEffect FRCmM-NA residual current circuit breakers (RCCBs) are ideal for sensing and disconnecting any low voltage (uneven current) circuit whenever a fault occurs. They are used in offices, industrial layouts and low-voltage applications.

Filter
StyleModelPrice
A
167114
£1,219.20
B
167110
£2,722.52
C
167694
£1,263.41
A
167698
£1,336.69
D
167693
£1,632.93
B
167709
£2,476.63
A
167697
£1,336.69
B
167703
£2,476.63
B
167705
£2,289.23
B
167104
-
RFQ
E
167120
£1,149.30
B
167111
£2,476.63
B
167699
£2,289.23
F
167695
-
RFQ
A
167696
£1,336.69
B
167700
£2,289.23
B
167704
£2,476.63
B
167707
£2,289.23
G
167102
£2,368.57
A
167124
£1,336.69
A
167122
£1,336.69
H
167115
£1,263.41
I
167109
-
RFQ
A
167117
£1,336.69
A
167123
-
RFQ
B
167112
£2,476.63
J
167119
£1,346.91
B
167708
£2,476.63
K
167103
£2,289.23
L
167107
£2,222.57
A
167116
-
RFQ
A
167118
-
RFQ
M
167108
£2,289.23
N
167121
£1,263.41
B
167125
£2,677.97
B
167701
£2,289.23
B
167710
-
RFQ
B
167706
£2,289.23
B
167702
£2,481.97
A
167113
£1,263.41
B
167106
£2,897.18

Working Mechanism

  • During an earth fault, the residual current circuit breaker continuously detects and contrasts any differences in the current between the live and neutral wires (residual current value).
  • The residual current circuit breaker will trip if there is even a slight difference in the numbers, cutting off the circuit.

Features

  • Eaton xEffect FRCmM-NA RCCBs feature Type A and Type G/A capable of sensing residual pulsating DC offering surge current-proof of 250A and 3kA respectively.
  • They come with a unique test button 'T' to automatically test the function of residual current circuit breakers (RCCB) themselves.
  • These RCCBs devices further feature independent line voltage tripping and operation temperature range of -25 to 40 degrees C.
  • They offer delayed tripping suitable with conventional fluorescent tubes, irrespective of whether electronic ballast is present or not.
  • These circuit breakers provide a tripping indicator and a contact position indicator for additional safety.

Standards and Approvals

  • IEC
  • EN 61008
  • UL

Frequently Asked Questions

What is the rated short circuit capacity of Eaton xEffect FRCmM-NA RCCBs?

5kA (according to CSA)

What is the rated tripping current of these residual current breakers?

30 / 300mA

How do we connect an FRCmM-NA residual current device?

  • RCCB is connected parallel to the miniature circuit breaker (MCB) into the distribution boards.
  • The phase is connected in parallel with the MCB and the neutral connection is done with neutral lines.

We are here to help!

Looking for a part not listed here?