Sign In

EATON GD Series Complete Molded Case Circuit Breakers, G Frame

Eaton GD Series moulded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
StyleModelMPNPrice
A
GD3050A3S7
GD3050A3S7£3,996.19
B
GD3050C
GD3050C£1,645.50
B
GD3050CA3
GD3050CA3£2,325.77
B
GD3050D
GD3050D£1,577.07
B
GD3050DA3
GD3050DA3£2,453.96
B
GD3050DS101
GD3050DS101-
RFQ
B
GD3050DV
GD3050DV£1,524.23
C
GD3060
GD3060£557.78
D
GD3060A3
GD3060A3£2,453.96
D
GD3060A3S7
GD3060A3S7£3,996.19
D
GD3060C
GD3060C£1,488.11
D
GD3060D
GD3060D£1,524.23
D
GD3060D1S3
GD3060D1S3£3,316.19
D
GD3060DA3
GD3060DA3£2,371.75
D
GD3060DS3
GD3060DS3£3,316.19
D
GD3060G1
GD3060G1-
RFQ
D
GD3060G2
GD3060G2£1,550.50
D
GD3060S1
GD3060S1£3,247.20
E
GD3070
GD3070£693.00
F
GD3070A3
GD3070A3-
RFQ
F
GD3070A3S7
GD3070A3S7£4,413.38
F
GD3070C
GD3070C-
RFQ
F
GD3070D
GD3070D£1,941.45
F
GD3070DA3
GD3070DA3-
RFQ
F
GD3070G2
GD3070G2£1,977.55
F
GD3070S1
GD3070S1-
RFQ
F
GD3070S3
GD3070S3£2,695.34
G
GD3080
GD3080£693.00
H
GD3080A3S7
GD3080A3S7£4,413.38
H
GD3080C
GD3080C£1,964.18
H
GD3080CA3
GD3080CA3£2,739.68
H
GD3080D
GD3080D-
RFQ
H
GD3080DA3
GD3080DA3£2,788.94
H
GD3080S1
GD3080S1£3,743.21
H
GD3080S3
GD3080S3-
RFQ
H
GD3080S4
GD3080S4£3,872.95
I
GD3090
GD3090£693.00
J
GD3090A3
GD3090A3£2,885.59
J
GD3090A3S1
GD3090A3S1£4,392.02
J
GD3090C
GD3090C£1,488.11
J
GD3090D
GD3090D£1,941.45
D
GD3090D1S3
GD3090D1S3£3,758.03
J
GD3090DA3
GD3090DA3£2,788.94
J
GD3090DS3
GD3090DS3£3,758.03
J
GD3090S1
GD3090S1£3,743.21
K
GD3100
GD3100-
RFQ
L
GD3100A3
GD3100A3£2,873.69
L
GD3100A3S7
GD3100A3S7£4,413.38
L
GD3100C
GD3100C-
RFQ
L
GD3100D
GD3100D£1,941.45
L
GD3100DA3
GD3100DA3£2,788.94
L
GD3100DS4
GD3100DS4£3,743.21
L
GD3100G2
GD3100G2£1,977.55
L
GD3100S1
GD3100S1-
RFQ
L
GD3100S4
GD3100S4£3,695.62

Working Mechanism

  • Eaton GD Series moulded case circuit breakers feature fixed thermal and fixed magnetic trips to protect against faulty currents:

Fixed Thermal Trips

  • The thermal trip consists of a bimetallic strip which gets heated and bends when an overcurrent passes through the conductors, which opens the contacts and interrupts the current flow.

Fixed Magnetic Trips

  • The magnetic trip has an electromagnetic component that detects the presence of short circuits in a circuit.
  • As the current rises, a magnetic field is generated that trips the breaker and causes the contacts to open and stop the current flow.

Features

  • These units feature a fixed thermal and fixed magnetic trip unit to avoid nuisance tripping in mild current fluctuation but are highly sensitive to heavy inrush current, thus producing both instantaneous and time-delayed current limiting protection.
  • They have a compact, space-saving design that provides installation in tight spaces and allows for high-speed blow-open action, resulting in superior performance.
  • They are integrated with line and load side terminals for easy installation with panelboards and load centres.
  • These MCCBs also include a toggle and a mechanical latching mechanism that ensures the circuit breaker remains in the tripped position until it is manually reset.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the advantage of moulded cases?

Moulded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

What is the purpose of a G-frame?

A G-frame is a modular design that provides a versatile and flexible platform to accommodate low-voltage circuit breakers. They also protect electrical systems from damage caused by overloads and short circuits, as well as mechanical stress.

What is the purpose of a toggle?

These circuit breakers come with an integrated over-centre toggle for visual indication of tripped status.

We are here to help!

Looking for a part not listed here?