Sign In

EATON GD Series Complete Molded Case Circuit Breakers, G Frame

Eaton GD Series moulded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
Frame Type: GD , Voltage: 480V
StyleModelAIC RatingAmpsNumber of PolesPrice
A
GD3035DA3
---£2,499.66
RFQ
B
GD2035C
---£911.32
RFQ
B
GD2030C
---£911.32
RFQ
C
GD3100G2
---£2,084.59
RFQ
B
GD2030D
---£911.32
RFQ
C
GD3100A3S7
---£4,654.35
RFQ
B
GD2035A3
---£1,831.86
RFQ
C
GD3100D
---£2,045.84
RFQ
B
GD2035DA3
---£1,831.86
RFQ
C
GD3100C
---£1,970.21
RFQ
C
GD3100DS4
---£3,945.95
RFQ
B
GD2025
---£911.32
RFQ
B
GD2035D
---£911.32
RFQ
C
GD3100S4
---£3,896.15
RFQ
B
GD2045C
---£911.32
RFQ
C
GD3100S1
---£3,945.95
RFQ
B
GD2050C
---£911.32
RFQ
B
GD2050A3
---£1,831.86
RFQ
B
GD2040C
---£911.32
RFQ
B
GD2040DA3
---£1,831.86
RFQ
C
GD3100DA3
---£2,940.57
RFQ
C
GD3100A3
---£2,927.64
RFQ
B
GD2050DV
---£1,606.79
RFQ
D
GD3080A3S7
---£4,654.35
RFQ
E
GD3070G2
---£2,084.59
RFQ
B
GD2015DA3
---£1,831.86
RFQ
D
GD3080C
---£1,970.21
RFQ
B
GD2025D
---£911.32
RFQ
D
GD3080S1
---£3,945.95
RFQ
B
GD2015DVB3
---£1,614.18
RFQ
F
GD3090DS3
---£3,962.57
RFQ
B
GD2020DB3
---£1,531.15
RFQ
B
GD2025C
---£911.32
RFQ
B
GD2025A3
---£1,831.86
RFQ
F
GD3090C
---£1,568.06
RFQ
B
GD2025V
---£911.32
RFQ
F
GD3090A3
---£2,940.57
RFQ
B
GD2030A3
---£1,831.86
RFQ
B
GD2025DV
---£911.32
RFQ
B
GD2030VA3
---£1,831.86
RFQ
G
GD3090D1S3
---£3,962.57
RFQ
D
GD3080S4
---£3,945.95
RFQ
B
GD2045
---£429.33
H
GD3015B3
---£2,451.69
RFQ
E
GD3070S3
---£2,840.95
RFQ
I
GD3020A3S7
---£4,213.46
RFQ
A
GD3035C
---£1,606.79
RFQ
A
GD3035
---£618.72
G
GD3060A3
---£2,499.66
RFQ
F
GD3090DA3
---£2,940.57
RFQ
F
GD3090S1
---£3,945.95
RFQ
B
GD2030DA3
---£1,831.86
RFQ
B
GD2040A3
---£1,831.86
RFQ
I
GD3020DA3
---£2,499.66
RFQ
I
GD3020DB3
---£2,499.66
RFQ
J
GD3030V
---£1,927.78
RFQ
I
GD3020DS1
---£3,495.84
RFQ
I
GD3020S1
---£3,423.89
RFQ
K
GD3025A3
---£2,499.66
RFQ
K
GD3025C
---£1,606.79
RFQ
K
GD3025S1
---£3,423.89
RFQ

Working Mechanism

  • Eaton GD Series moulded case circuit breakers feature fixed thermal and fixed magnetic trips to protect against faulty currents:

Fixed Thermal Trips

  • The thermal trip consists of a bimetallic strip which gets heated and bends when an overcurrent passes through the conductors, which opens the contacts and interrupts the current flow.

Fixed Magnetic Trips

  • The magnetic trip has an electromagnetic component that detects the presence of short circuits in a circuit.
  • As the current rises, a magnetic field is generated that trips the breaker and causes the contacts to open and stop the current flow.

Features

  • These units feature a fixed thermal and fixed magnetic trip unit to avoid nuisance tripping in mild current fluctuation but are highly sensitive to heavy inrush current, thus producing both instantaneous and time-delayed current limiting protection.
  • They have a compact, space-saving design that provides installation in tight spaces and allows for high-speed blow-open action, resulting in superior performance.
  • They are integrated with line and load side terminals for easy installation with panelboards and load centres.
  • These MCCBs also include a toggle and a mechanical latching mechanism that ensures the circuit breaker remains in the tripped position until it is manually reset.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the advantage of moulded cases?

Moulded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

What is the purpose of a G-frame?

A G-frame is a modular design that provides a versatile and flexible platform to accommodate low-voltage circuit breakers. They also protect electrical systems from damage caused by overloads and short circuits, as well as mechanical stress.

What is the purpose of a toggle?

These circuit breakers come with an integrated over-centre toggle for visual indication of tripped status.

We are here to help!

Looking for a part not listed here?