EATON FWF Series Complete Molded Case Circuit Breakers, F Frame

Eaton FWF Series complete molded case circuit breakers (MCCBs) protect electrical circuits and equipment from overloads, short circuits, and other electrical faults that can potentially damage the electrical system or cause hazards such as fires or electrical shocks.

Filter
StyleModelMPNPrice
A
FWF4025L
FWF4025L-
RFQ
A
FWF4032L
FWF4032L£4,938.29
A
FWF4040L
FWF4040L£4,938.29
A
FWF4050L
FWF4050L£5,128.84
A
FWF4063L
FWF4063L£4,938.29
A
FWF4080L
FWF4080L-
RFQ
A
FWF4100L
FWF4100L£4,938.29
A
FWF4160EL
FWF4160EL£11,116.11
A
FWF4160L
FWF4160L£11,116.11
A
FWF4175EL
FWF4175EL£12,685.97
A
FWF4175L
FWF4175L£12,685.97
B
FWF4200L
FWF4200L£12,685.97
RFQ
A
FWF4200LS
FWF4200LS£11,116.11
A
FWF4225L
FWF4225L£12,893.94
A
FWF40161L
FWF40161L£4,938.29
A
FWF42001L
FWF42001L£12,685.97

Features

  • Eaton FWF Series complete MCCBs have F-frames for high thermal resistance and increased flexibility in installation options.
  • They feature a fixed thermal-magnetic trip facilitating quick tripping actions during an overload or short circuit.
  • These circuit breakers have current ratings ranging from 100 to 225A.

Standards and Approvals

  • IEC

Frequently Asked Questions

What pole configurations do Eaton FWF Series complete MCCBs offer?

These MCCBs are offered in 1, 2, 3 and 4 pole configurations.

What is the recommended maintenance procedure for Eaton FWF Series complete MCCBs?

  • Examine the circuit breaker thoroughly for indications of wear or damage.
  • Verify that all connections are securely tightened by checking their torque.
  • Remove any dirt or debris from the circuit breaker and the surrounding vicinity.
  • Conduct a test on the MCCB to ensure that it's performing as intended.
  • Make sure the calibration settings are set within the recommended range.

What are the steps to install an Eaton FWF Series complete MCCBs?

  • To install an Eaton FWF Series complete MCCB, firstly disconnect the power supply to the circuit breaker.
  • Next, remove the cover of the circuit breaker panel or enclosure, and if required, install the mounting bracket for the MCCB.
  • Attach the MCCB to the mounting bracket and then connect the load wires to the appropriate terminals on the MCCB, followed by connecting the line wires to their appropriate terminals on the MCCB.
  • Finally, close the cover of the circuit breaker panel or enclosure and then turn on the power supply to the circuit breaker.