EATON FD Series Complete Molded Case Circuit Breakers, F Frame | Raptor Supplies United Kingdom
Sign In

EATON FD Series Complete Molded Case Circuit Breakers, F Frame

Eaton Series C molded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
StyleModelAmpsNumber Of PolesVoltagePrice
A
FD1030BP10
----
RFQ
B
FD3080LS22
---£4,595.00
B
FD3080LM08
----
RFQ
B
FD3150LA02
---£3,698.25
B
FD3070LM08
---£1,471.49
B
FD3150A02
---£3,694.35
B
FD3070VW
---£1,523.82
B
FD3125BP10
----
RFQ
C
FD3030VH09
---£1,430.04
B
FD3100VLM04
---£1,430.04
B
FD3020J01F01H08
---£1,941.39
B
FD3100H10
---£1,611.46
B
FD3015VL
---£1,355.83
D
FD2225H08
---£3,147.03
B
FD3080VL
----
RFQ
D
FD2225D22M03
---£2,879.64
D
FD2175L
---£2,887.46
B
FD3060VW
----
RFQ
D
FD2125V
---£2,869.48
B
FD3070BP10
----
RFQ
D
FD2100B06
---£1,686.50
B
FD3015LS
---£1,351.07
E
FD1025
---£448.40
B
FD3015H08
----
RFQ
D
FD2200LSB06D12MO3
---£3,300.29
D
FD2110L
---£2,771.73
D
FD2060LF01V4
----
RFQ
B
FD3150LC01S21
----
RFQ
B
FD3150LS02
---£3,991.47
D
FD2020VL
---£1,124.34
B
FD3150LA01
----
RFQ
B
FD3175A04
---£3,688.09
B
FD3175L
---£3,745.34
B
FD3150VA09U61
---£4,718.62
F
FD4015
---£2,137.05
B
FD3150LSA02
----
RFQ
G
FD3225VW
---£3,157.99
B
FD3150S02
---£3,983.64
G
FD3225LA02U82
----
RFQ
B
FD3150LB02
---£3,573.96
B
FD3150LF01S09
---£4,788.97
B
FD3200WA06
----
RFQ
B
FD3200LS21
---£4,249.48
B
FD3100LM08
---£1,471.49
B
FD3150A02S22
---£4,269.04
B
FD3200LD12M03
---£3,324.52
B
FD3125VL
---£3,414.64
B
FD3200A10S22D01
---£4,941.44
B
FD3125S21
----
RFQ
B
FD3125LS22
---£3,991.47
B
FD3175LA04
---£3,694.35
B
FD3175BP10
----
RFQ
B
FD3125LA02
----
RFQ
B
FD3150S17
---£3,983.64
B
FD3110LW02
----
RFQ
B
FD3150LU14
---£4,120.47
D
FD2030VL
----
RFQ
E
FD1125
---£1,254.87
B
FD3175V
---£3,295.58
F
FD4070E
---£2,248.64
F
FD4030E
---£2,248.64

Working Mechanism

  • Eaton molded case circuit breakers are equipped with fixed thermal and fixed magnetic trips.
  • The thermal trip comprises a bi-metallic strip that gets heated when an overcurrent passes through the conductors, causing the contacts to open and interrupt the current flow.
  • The magnetic trip, on the other hand, has an electromagnetic component that detects the presence of a short circuit.
  • As the current rises abruptly, a magnetic field is created that causes the displacement in the tripping coil.
  • This opens the contact again and stops the current flow, preventing any further damage to the equipment.

Features

  • These circuit breakers feature a non-interchangeable, thermal-magnetic trip that avoids nuisance tripping on mild overloads while reacting instantly when exposed to faulty currents, thus providing maximum protection.
  • They feature a contact design that offers high-speed blow-open action, resulting in superior performance and eliminating the risk of potential hazards.
  • These FD Series complete MCCBs come with an enhanced, easy-to-use interface, allowing the operator to view and make adjustments to the trip settings.
  • They are integrated with load-side terminals for easy installation with panelboards and load centres.

Standards and Approvals

  • UL

Frequently Asked Questions

How to maintain the frame of these molded case circuit breakers?

  • Inspect the frame regularly for any signs of damage or wear like cracks, chips or corrosion.
  • Use a soft brush or cloth to remove any dirt, dust or debris from the frame.
  • Always lubricate moving parts of the frame including hinges or latches to ensure smooth operation.

What is the function of molded cases?

Molded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

We are here to help!

Looking for a part not listed here?