Sign In

EATON EHD Series Complete Molded Case Circuit Breakers, F Frame

Eaton EHD Series molded case circuit breakers are suitable for providing circuit protection against overcurrent conditions. They are available in single, double and three-pole configurations.

Filter
StyleModelMPNPrice
A
EHD1010
EHD1010£293.02
A
EHD1010L
EHD1010L£205.97
A
EHD1010WD01
EHD1010WD01£296.95
A
EHD1015B15
EHD1015B15£527.78
A
EHD1015BP10
EHD1015BP10-
RFQ
A
EHD1015L
EHD1015L£213.14
A
EHD1015LBP10
EHD1015LBP10-
RFQ
A
EHD1015LZ04
EHD1015LZ04£209.35
A
EHD1015V
EHD1015V£204.25
A
EHD1015W
EHD1015W-
RFQ
A
EHD1015WD01
EHD1015WD01-
RFQ
A
EHD1015Z01
EHD1015Z01£204.25
A
EHD1015Z04
EHD1015Z04£203.33
A
EHD1020B15
EHD1020B15£527.78
A
EHD1020BP10
EHD1020BP10£203.18
A
EHD1020H01
EHD1020H01£241.16
A
EHD1020H08
EHD1020H08£222.27
A
EHD1020LBP10
EHD1020LBP10-
RFQ
A
EHD1020LZ04
EHD1020LZ04-
RFQ
A
EHD1020V
EHD1020V£214.62
A
EHD1020VB15
EHD1020VB15£527.78
A
EHD1020VW
EHD1020VW£208.53
A
EHD1020VZ04
EHD1020VZ04£196.52
A
EHD1020Y
EHD1020Y-
RFQ
A
EHD1020Z01
EHD1020Z01£204.25
A
EHD1020Z04
EHD1020Z04£196.52
A
EHD1025L
EHD1025L£205.97
A
EHD1025WD01
EHD1025WD01£225.57
A
EHD1030B15
EHD1030B15£527.78
A
EHD1030BP10
EHD1030BP10£195.50
A
EHD1030L
EHD1030L£425.07
A
EHD1030LB15
EHD1030LB15£529.50
A
EHD1030LB15M01
EHD1030LB15M01£529.50
A
EHD1030LBP10
EHD1030LBP10£181.52
A
EHD1030LM01
EHD1030LM01£205.97
A
EHD1030VL
EHD1030VL-
RFQ
A
EHD1030WD01
EHD1030WD01£217.97
A
EHD1035
EHD1035£198.24
A
EHD1035L
EHD1035L£199.95
A
EHD1040B15
EHD1040B15-
RFQ
A
EHD1040L
EHD1040L£213.14
A
EHD1040WD01
EHD1040WD01£439.39
A
EHD1045
EHD1045£293.02
A
EHD1045L
EHD1045L-
RFQ
B
EHD1050L
EHD1050L-
RFQ
A
EHD1060
EHD1060£293.02
B
EHD1060L
EHD1060L-
RFQ
A
EHD1070
EHD1070£317.21
B
EHD1070L
EHD1070L£379.31
B
EHD1070WD01
EHD1070WD01£453.99
A
EHD1080
EHD1080£317.21
B
EHD1080L
EHD1080L£385.53
C
EHD1090
EHD1090£317.21
B
EHD1090L
EHD1090L£379.31
D
EHD1100
EHD1100£317.21
B
EHD1100H08
EHD1100H08£411.93
B
EHD1100L
EHD1100L£379.31
E
EHD2010
EHD2010-
RFQ
F
EHD2010A06
EHD2010A06£1,043.59
F
EHD2010LA08
EHD2010LA08-
RFQ
F
EHD2010LM03
EHD2010LM03-
RFQ

Working Mechanism

  • Eaton EHD series MCCBs are equipped with fixed thermal and fixed magnetic trip units to protect the system against overload and short-circuit conditions.

Fixed Thermal Trip:

  • This protection device features a bi-metallic strip and operates based on the heating effects of current.
  • The heat generated during an overcurrent situation causes the bimetallic strip to bend. This opens the circuit breaker and interrupts the current flow.

Fixed Magnetic Trip:

  • This trip consists of an electromagnet and operates on the principle of the magnetic effect of current.
  • When the current passing through a circuit exceeds a pre-determined value, the electromagnet senses the magnetic field generated by the current and opens the breaker to stop the flow.

Features

  • These F-frame breakers have high interrupting ratings that allow them to safely interrupt short-circuit currents up to 18kA.
  • They feature interchangeable (fixed thermal & fixed magnetic) trip units suitable for reverse feed applications.
  • They also include a manual trip option controlled by the breaker's toggle handle and a PUSH-TO-TRIP button to trip during a power failure or for troubleshooting purposes.
  • Selected circuit breakers are equipped with terminals on the load end and are designed to withstand temperatures up to 50 degrees Celsius.

Standards and Approvals

  • UL
  • HACR

Frequently Asked Questions

How to install the circuit breaker?

  • Inspect the circuit breaker for completeness and check for any damage before installation.
  • Position the circuit breaker on the mounting surface. Install mounting screws, washers and nuts and tighten firmly.
  • Connect the load terminals (if required) and accessories to the circuit breaker.
  • Test the breaker and ensure it is working properly.

How do I reset Eaton EHD Series circuit breakers once tripped?

After tripping, the circuit breaker can be reset by moving the toggle handle to the extreme OFF position. However, during a thermal trip, the circuit breaker cannot be reset until the thermal element (bi-metallic strip) cools down.

What is the PUSH-TO-TRIP button used for?

The PUSH-TO-TRIP button is used for checking the tripping function and periodically exercising the operating mechanism to ensure the proper working of the circuit breaker.

We are here to help!

Looking for a part not listed here?