Sign In

EATON CH Series Standard Circuit Breakers

Eaton CH Series standard circuit breakers are installed in CH-type loadcenters for preventing electrical damage to connected devices due to excess current or short circuits. They have a plug-on type ...Read More

Filter
AIC Rating: 42kAIC@240V , Frame Type: CHH , Number of Poles: 2
StyleModelAmpsVoltagePrice
A
CH310
--£192.78
B
CH345
---
RFQ
C
CH350ST
---
RFQ
D
CH3100
--£339.98
E
CH315HID
--£539.15
RFQ
F
CH315SW
--£205.52
G
CH350
--£185.74
C
CH320ST
--£556.25
H
CH330
--£179.91
C
CH315ST
---
RFQ
I
CH320
--£179.91
J
CH320SWST
--£415.23
RFQ
F
CH320SW
--£138.80
RFQ
K
CH325
--£188.73
L
CH370
--£297.36
E
CH330HID
--£539.15
RFQ
C
CH360ST
--£556.25
C
CH3090ST
--£685.59
C
CH370ST
--£614.94
F
CH340SW
--£172.79
RFQ
C
CH340ST
--£556.25
M
CH315
--£179.91
N
CH335
---
RFQ
O
CH120
--£18.90
RFQ
P
CH270
--£140.85
Q
CH290ST
---
RFQ
C
CH3080ST
--£685.59
R
CH3090
--£327.67
C
CH3100ST
---
RFQ
S
CH340
--£185.74
T
CH360
--£185.74
C
CH345ST
--£504.00
RFQ
U
CH160
---
RFQ
R
CH3080
---
RFQ
C
CH330ST
--£556.25
Q
CH2125ST
---
RFQ
V
CH160ST
--£254.38
RFQ
W
CH170
--£63.17
RFQ
V
CH170ST
--£288.34
RFQ
X
CH2100CS
--£179.32
RFQ
Y
CH2100X
---
RFQ
Z
CH2125
--£366.39
RFQ
A1
CH2100
--£140.85
Q
CH2100ST
---
RFQ
B1
CH2100N
--£200.77
RFQ
C1
CH2110CS
--£373.52
RFQ
B1
CH2125N
--£466.47
RFQ
Y
CH2125X
--£461.85
Y
CH2150X
---
RFQ
D1
CH2125CS
--£373.52
RFQ
E1
CH2110
--£339.98
F1
CH280
--£148.11
G1
CH2150
---
RFQ
H1
CH220HID
--£174.54
RFQ
I1
CH220M50
--£64.36
RFQ
J1
CH220SWST
--£394.97
RFQ
H1
CH230HID
--£212.69
RFQ
J1
CH230SWST
--£363.40
RFQ
K1
CH260CS
--£84.02
RFQ
L1
CH260
--£95.01
I1
CH250M50
--£64.36
RFQ

Features

  • Eaton CH Series circuit breakers have a sliding handle with ON & OFF indication positions for easy identification of the breaker's status.
  • They have 1 / 2 / 3-poles for application-specific performance.
  • Their thermal-magnetic trip mechanism prevents nuisance tripping due to mild overloads while acting almost instantaneously during severe short-circuit conditions.
  • Eaton CH Series circuit breakers having more than one pole are equipped with an internal common trip connection for simultaneous operation of the poles.
  • They have a quick-make & quick-break switch mechanism for safe & efficient operation.
  • These circuit breakers require 3/4-inch (19.1 mm) space per pole for installation.
  • Selected models have a clamshell pack for enhanced durability, an MCB kit for easy installation on MCBs and a shunt trip for tripping the breakers remotely at any time.

Compatible Accessories

  • Eaton CHHT Handle Tie Bar: This handle tie bar with a moulded plastic handle cover can physically join the handles of adjacent CH type circuit breakers having a single pole.
  • Eaton CHPL Handle Lockoff: This is a padlockable device that locks the handle of escutcheon-mounted CH-type circuit breakers.
  • Eaton CHML Mechanical Interlock: It secures & locks 2, 3 & 4-pole CH type breakers.

Standards and Approvals

  • UL 489

Frequently Asked Questions

What is the voltage rating of these Eaton CH Series circuit breakers?

Eaton CH Series circuit breakers have a voltage rating of 120 / 240V and an interrupt rating of 10kAIC.

What are the points to inspect before operating these Eaton CH Series circuit breakers?

  • Remove the dust, dirt, grease, moisture or foreign contaminants from the unit.
  • Check that the unit's switch is free to move by switching the unit ON & OFF several times.
  • Inspect the unit for any cracks, chipping or discolouration. Tighten the terminals & connectors. Check the mounting hardware.
  • Remove any safety hazards near the installed area.

What wire gauges are suitable for wiring these Eaton CH Series circuit breakers?

  • #10-1/0 AWG
  • #14-2 AWG
  • #14-8 AWG

We are here to help!

Looking for a part not listed here?