EATON CH Series Standard Circuit Breakers | Raptor Supplies United Kingdom
Sign In

EATON CH Series Standard Circuit Breakers

Eaton CH Series standard circuit breakers are installed in CH-type loadcenters for preventing electrical damage to connected devices due to excess current or short circuits. They have a plug-on type ...Read More

Filter
StyleModelAmpsVoltagePrice
A
CH120
--£52.17
B
CH315
--£171.71
C
CH3080
--£347.22
D
CH3090ST
---
RFQ
C
CH3090
--£347.22
E
CH310
--£197.87
D
CH3100ST
--£1,499.78
F
CH3100
--£347.22
G
CH340SW
--£176.95
D
CH340ST
--£598.73
H
CH330
--£171.71
I
CH340
--£177.68
D
CH345ST
--£1,479.74
J
CH370
--£300.16
D
CH360ST
---
RFQ
D
CH320ST
--£575.05
D
CH315ST
--£1,479.74
K
CH160ST
---
RFQ
L
CH320
--£171.71
M
CH320SWST
--£1,218.22
D
CH330ST
--£575.05
N
CH335
--£203.99
O
CH360
--£177.68
P
CH315HID
--£1,583.07
G
CH320SW
--£142.15
Q
CH325
--£187.08
P
CH330HID
--£1,583.07
R
CH345
--£203.99
D
CH350ST
---
RFQ
S
CH350
--£177.68
G
CH315SW
--£209.74
M
CH350SWST
--£1,201.05
D
CH3080ST
--£699.27
T
CH280
--£152.62
U
CH290ST
---
RFQ
V
CH270
--£141.04
K
CH170ST
--£848.70
W
CH2100X
--£1,528.30
X
CH2100
--£152.62
Y
CH2100N
--£591.94
Y
CH2125N
--£1,370.11
W
CH2150X
--£830.34
U
CH2125ST
--£1,930.66
Z
CH2150
--£575.05
A1
CH220M50
--£195.61
B1
CH230HID
--£626.34
C1
CH260CS
--£86.05
A1
CH250M50
--£65.91
A1
CH270M50
--£156.20
U
CH270ST
--£1,195.02
D1
CH160
--£59.80
E1
CH170
--£187.42
F1
CH2110
--£347.22
G1
CH290
--£180.58
U
CH280ST
---
RFQ
U
CH260ST
--£360.19
H1
CH260
--£106.88
I1
CH230SWST
---
RFQ
I1
CH220SWST
--£1,160.28
B1
CH220HID
--£525.49
J1
CH2125CS
---
RFQ

Features

  • Eaton CH Series circuit breakers have a sliding handle with ON & OFF indication positions for easy identification of the breaker's status.
  • They have 1 / 2 / 3-poles for application-specific performance.
  • Their thermal-magnetic trip mechanism prevents nuisance tripping due to mild overloads while acting almost instantaneously during severe short-circuit conditions.
  • Eaton CH Series circuit breakers having more than one pole are equipped with an internal common trip connection for simultaneous operation of the poles.
  • They have a quick-make & quick-break switch mechanism for safe & efficient operation.
  • These circuit breakers require 3/4-inch (19.1 mm) space per pole for installation.
  • Selected models have a clamshell pack for enhanced durability, an MCB kit for easy installation on MCBs and a shunt trip for tripping the breakers remotely at any time.

Compatible Accessories

  • Eaton CHHT Handle Tie Bar: This handle tie bar with a moulded plastic handle cover can physically join the handles of adjacent CH type circuit breakers having a single pole.
  • Eaton CHPL Handle Lockoff: This is a padlockable device that locks the handle of escutcheon-mounted CH-type circuit breakers.
  • Eaton CHML Mechanical Interlock: It secures & locks 2, 3 & 4-pole CH type breakers.

Standards and Approvals

  • UL 489

Frequently Asked Questions

What is the voltage rating of these Eaton CH Series circuit breakers?

Eaton CH Series circuit breakers have a voltage rating of 120 / 240V and an interrupt rating of 10kAIC.

What are the points to inspect before operating these Eaton CH Series circuit breakers?

  • Remove the dust, dirt, grease, moisture or foreign contaminants from the unit.
  • Check that the unit's switch is free to move by switching the unit ON & OFF several times.
  • Inspect the unit for any cracks, chipping or discolouration. Tighten the terminals & connectors. Check the mounting hardware.
  • Remove any safety hazards near the installed area.

What wire gauges are suitable for wiring these Eaton CH Series circuit breakers?

  • #10-1/0 AWG
  • #14-2 AWG
  • #14-8 AWG

We are here to help!