EATON CH Series Standard Circuit Breakers | Raptor Supplies United Kingdom
Sign In

EATON CH Series Standard Circuit Breakers

Eaton CH Series standard circuit breakers are installed in CH-type loadcenters for preventing electrical damage to connected devices due to excess current or short circuits. They have a plug-on type ...Read More

Filter
StyleModelAmpsVoltagePrice
A
CH2100
--£149.03
B
CH280ST
---
RFQ
C
CH3080
--£339.05
C
CH3090
--£339.05
D
CH310
--£193.21
E
CH3100ST
--£1,464.49
F
CH315
--£167.67
G
CH320
--£167.67
H
CH325
--£182.68
I
CH330HID
--£1,545.82
J
CH330
--£167.67
K
CH335
--£199.19
L
CH340
--£173.50
M
CH360
--£173.50
N
CH350SWST
--£1,172.79
E
CH360ST
---
RFQ
O
CH290
--£176.33
B
CH2100ST
--£619.28
E
CH350ST
---
RFQ
P
CH170ST
--£828.73
Q
CH370
--£293.09
E
CH345ST
--£1,444.93
R
CH350
--£173.50
E
CH340ST
--£584.64
S
CH340SW
--£172.79
T
CH345
--£199.19
B
CH290ST
---
RFQ
E
CH330ST
--£561.52
S
CH320SW
--£138.80
E
CH320ST
--£561.52
S
CH315SW
--£204.81
E
CH3090ST
---
RFQ
E
CH3080ST
--£682.81
U
CH280
--£149.03
V
CH270
--£137.72
B
CH270ST
--£1,166.90
W
CH270M50
--£152.53
X
CH2110CS
--£1,027.64
Y
CH2125X
--£1,492.34
Y
CH2150X
--£810.80
Z
CH220SWST
--£1,132.98
A1
CH230HID
--£611.60
Z
CH230SWST
---
RFQ
B1
CH260CS
--£84.02
C1
CH260
--£104.37
W
CH250M50
--£64.36
D1
CH3100
--£339.05
I
CH315HID
--£1,545.82
E
CH315ST
--£1,444.93
N
CH320SWST
--£1,189.55
E
CH370ST
--£619.28
E1
CH120
--£50.94
F1
CH2100CS
--£545.89
G1
CH2125N
--£1,337.87
B
CH260ST
--£351.72
W
CH220M50
--£191.00
A1
CH220HID
--£513.12
H1
CH2150
--£561.52
I1
CH2110
--£339.05
B
CH2125ST
--£1,885.23
J1
CH2125CS
---
RFQ

Features

  • Eaton CH Series circuit breakers have a sliding handle with ON & OFF indication positions for easy identification of the breaker's status.
  • They have 1 / 2 / 3-poles for application-specific performance.
  • Their thermal-magnetic trip mechanism prevents nuisance tripping due to mild overloads while acting almost instantaneously during severe short-circuit conditions.
  • Eaton CH Series circuit breakers having more than one pole are equipped with an internal common trip connection for simultaneous operation of the poles.
  • They have a quick-make & quick-break switch mechanism for safe & efficient operation.
  • These circuit breakers require 3/4-inch (19.1 mm) space per pole for installation.
  • Selected models have a clamshell pack for enhanced durability, an MCB kit for easy installation on MCBs and a shunt trip for tripping the breakers remotely at any time.

Compatible Accessories

  • Eaton CHHT Handle Tie Bar: This handle tie bar with a moulded plastic handle cover can physically join the handles of adjacent CH type circuit breakers having a single pole.
  • Eaton CHPL Handle Lockoff: This is a padlockable device that locks the handle of escutcheon-mounted CH-type circuit breakers.
  • Eaton CHML Mechanical Interlock: It secures & locks 2, 3 & 4-pole CH type breakers.

Standards and Approvals

  • UL 489

Frequently Asked Questions

What is the voltage rating of these Eaton CH Series circuit breakers?

Eaton CH Series circuit breakers have a voltage rating of 120 / 240V and an interrupt rating of 10kAIC.

What are the points to inspect before operating these Eaton CH Series circuit breakers?

  • Remove the dust, dirt, grease, moisture or foreign contaminants from the unit.
  • Check that the unit's switch is free to move by switching the unit ON & OFF several times.
  • Inspect the unit for any cracks, chipping or discolouration. Tighten the terminals & connectors. Check the mounting hardware.
  • Remove any safety hazards near the installed area.

What wire gauges are suitable for wiring these Eaton CH Series circuit breakers?

  • #10-1/0 AWG
  • #14-2 AWG
  • #14-8 AWG

We are here to help!

Looking for a part not listed here?