CHERNE MS2 Long Test Ball Plugs

Cherne MS2 long Test Ball plugs are ideal for waste stack testing from floor drains to sewer pipes.

Filter
StyleModelNominal SizeRangeMax. Back PressureRequired Inflation PressureDeflated LengthDeflated DiameterPrice
A
274518
2" to 3"1.75" To 3.25"13 psi/30 ft.40 psi19.44"1.58"£135.80
B
274526
3" to 4"2.75" To 4.25"13 psi/30 ft.40 psi23.75"2.38"£160.50
B
274534
4" to 6"3.5" To 6.25"13 psi/30 ft.30 psi26.62"3.25"£392.28

Working Mechanism

  • The plugs should be positioned into the pipe at a distance at least equal to the pipe diameter.
  • Connect one end of the inflation hose to the plug inflation fitting.
  • Brace / block the plug.
  • Inflate pressure to the plug through the inflation hose and let it stabilise.
  • Proceed with the testing of pipe or other use of the plug.
  • Release plug pressure from outside the danger zone until the plug is completely deflated and finally remove bracing / blocking system.

Features

  • Cherne MS2 long Test Ball plugs come with moulded-in sealing ribs to guarantee a leak-free seal.
  • They are long enough to seal sewer run and wye vertical riser.
  • 274518, 274526 and 274534 models allow multi-stage deflation to remove backsplash.
  • They have pressure relief guard to protect against over-inflation.
  • These units include a 5 ft extension hose, safety handle & nylon strap to prevent the plug from sliding down.

Standards and Approvals

  • ISO 9001
  • OSHA

Frequently Asked Questions

What is the shelf life of Cherne pneumatic plugs?

Cherne offers a 2-year warranty on all pneumatic plugs (from the date of manufacture) when kept under controlled conditions and at temperatures between 0 and 125 degrees Fahrenheit.

How often should the pressure of the plugs be monitored?

The inflation pressure should be checked and maintained a minimum of once per 4 hours while in use.

What will happen during over-inflation or under-inflation of the plugs?

  • Over-inflation: It may cause the plug to dislodge and rupture at extreme velocity.
  • Under-inflation: It may cause the media and the plug restrained to dislodge from the pipe.