BUSSMANN Time Delay Class D - Milk Bottle Fuses | Raptor Supplies United Kingdom
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.
Sign In

BUSSMANN Time Delay Class D - Milk Bottle Fuses

Bussmann Class D fuses protect motors, fans, blowers, conveyors and HVAC systems from electrical faults, minimising downtime and ensuring operational reliability.

Filter
StyleModelColor CodeDiameterFunctionally Equal ToFuse AmpsLengthPrice
A
35D33
Black27.5mmSiemens 5SB4-113550ft.£35.54
B
20D27
Blue21.5mmSiemens 5SB2-712050ft.£19.84
C
4D27
Brown21.5mmSiemens 5SB2-21450ft.£22.68
D
4GD27
Brown27/32"Siemens 5SB242"£6.41
C
4D16
Brown13.2mmSiemens 5SA2-2450ft.£27.01
E
63D33
Copper27.5mmSiemens 5SB4-116350ft.£38.24
F
6D27
Green21.5mmSiemens 5SB2-31650ft.£26.18
G
16D27
Grey21.5mmSiemens 5SB2-611650ft.£23.90
H
2D27
Pink21.5mmSiemens 5SB2-11250ft.£22.75
I
10D27
Red21.5mmSiemens 5SB2-511050ft.£19.65
I
10D16
Red13.2mmSiemens 5SA2-511050ft.£22.06
D
100D125
Red1 1/3"Siemens 5SC2-211002.25"£62.56
J
50D33
White27.5mmSiemens 5B45050ft.£38.14
K
25D27
Yellow21.5mmSiemens 5SB2-812550ft.£24.66

Features

  • Bussmann time delay Class D fuses feature white ceramic construction for durability and temperature resistance.
  • They have an interrupt rating of 50kA at 500VAC and are available in amperage ratings ranging from 2A to 100A.
  • These fuses have time-delayed speed to protect against temporary overloads.

Frequently Asked Questions

What are bottle fuses?

The bottle fuses are types of fuses with variable-sized ends used in small electrical systems to protect circuits from short circuits and overcurrents. These bottle fuses prevent incorrect insertion of wrong fuses into a circuit.

What is the difference between fusible and non-fusible switches?

Fusible switches are equipped with integrated fuses that offer overcurrent protection for electrical circuits, while non-fusible switches lack built-in fuses and rely on other protective devices, such as circuit breakers or upstream fuses, to provide overcurrent protection in the circuit.

How to maintain Bussmann time delay Class D fuses?

  • Ensure the fuse and surrounding components are clean and free from debris.
  • Store the fuses in a dry, clean and well-ventilated area.
  • Verify that the voltage and current ratings match the circuit requirements.
  • Ensure the electrical circuit does not carry a current higher than the fuse's rated capacity.

We are here to help!

Looking for a part not listed here?