Sign In

BUSSMANN LPJ Low-Peak Time Delay Fuses, Dual Element, Class J, With Indictaor

Filter
StyleModelBody StyleClassConnection TypeCurrent RatingDiameterFuse AmpsFuse Holder CodeIndicating / NonindicatingPrice
A
LPJ-350SPI
BladeJ--2.125"350ADIndicating£754.57
B
LPJ-150SPI
BladeJ--1.625"150ACIndicating£200.40
C
LPJ-70SPI
BladeJ--1.125"70-Indicating£87.28
D
LPJ-300SP
BladeJ--2.125"300ADNonindicating£289.89
E
LPJ-175SP
BladeJ--1.625"175ACNonindicating£168.31
D
LPJ-90SP
BladeJ--1.125"90ABNonindicating£84.66
F
LPJ-300SPI
BladeJ--2.125"300ADIndicating£760.34
A
LPJ-250SPI
BladeJ--2.125"250ADIndicating£329.95
B
LPJ-175SPI
BladeJ--1.625"175ACIndicating£227.00
C
LPJ-90SPI
BladeJ--1.125"90ABIndicating£95.32
D
LPJ-80SP
BladeJ--1.125"80ABNonindicating£84.66
A
LPJ-225SPI
BladeJ--2.125"225ADIndicating£320.34
G
LPJ-200SPI
BladeClass JBolted Blade End x Bolted Blade End200A1 5/8"200ACIndicating£200.40
D
LPJ-150SP
BladeJ--1.625"150ACNonindicating£161.84
H
LPJ-450SPI
BladeJ--2.593450-Indicating£468.96
G
LPJ-125SPI
BladeClass JBolted Blade End x Bolted Blade End125A1 5/8"125ACIndicating£200.40
B
LPJ-110SPI
BladeJ--1.625"110ACIndicating£401.03
C
LPJ-100SPI
BladeJ--1.125"100ABIndicating£95.32
A
LPJ-400SPI
BladeJ--2.125"400ADIndicating£352.93
E
LPJ-200SP
BladeJ--1.625"200ACNonindicating£161.84
C
LPJ-80SPI
BladeJ--1.125"80ABIndicating£216.93
I
LPJ-450SP
BladeJ--2.593450-Nonindicating£461.42
H
LPJ-600SPI
BladeJ--2.593600-Indicating£468.96
H
LPJ-500SPI
BladeJ--2.593500-Indicating£468.96
J
LPJ-30SPI
CylindericalClass JFerrule End x Ferrule End30A13/16"30ZIndicating£22.82
K
LPJ-60SPI
CylindericalClass JFerrule End x Ferrule End60A1 1/16"60AAIndicating£109.90
L
LPJ-17-1/2SPI
CylindricalJ--13/16"17.5ZIndicating£29.01
L
LPJ-15SPI
CylindricalJ--13/16"15ZIndicating£22.82
M
LPJ-2-1/2SP
CylindricalJ--13/16"2.5ZNonindicating£23.82
M
LPJ-2-1/4SP
CylindricalJ--13/16"2.25ZNonindicating£24.17
N
LPJ-50SP
CylindricalJ--1 1/16"50AANonindicating£37.62
M
LPJ-5SP
CylindricalJ--13/16"5ZNonindicating£21.20
M
LPJ-6SP
CylindricalJ--13/16"6ZNonindicating£21.26
O
LPJ-8SP
CylindricalJ--13/16"8ZNonindicating£21.26
N
LPJ-10SP
CylindricalJ--13/16"10ZNonindicating£21.26
N
LPJ-25SP
CylindricalJ--13/16"25ZNonindicating£19.62
N
LPJ-45SP
CylindricalJ--13/16"45AANonindicating£40.69
M
LPJ-1-1/4SP
CylindricalJ--13/16"1.25ZNonindicating£25.95
L
LPJ-9SPI
CylindricalJ--13/16"9ZIndicating£26.81
M
LPJ-7SP
CylindricalJ--13/16"7ZNonindicating£21.20
L
LPJ-8SPI
CylindricalJ--13/16"8ZIndicating£26.81
N
LPJ-20SP
CylindricalJ--13/16"20ZNonindicating£19.62
P
LPJ-4-1/2SP
CylindricalJ--13/16"4.5ZNonindicating£24.17
L
LPJ-6SPI
CylindricalJ--13/16"6ZIndicating£25.95
L
LPJ-10SPI
CylindricalJ--13/16"10ZIndicating£22.54
B
LPJ-12SPI
CylindricalJ--13/16"12ZIndicating£22.54
L
LPJ-20SPI
CylindricalJ--13/16"20ZIndicating£22.82
L
LPJ-25SPI
CylindricalJ--13/16"25ZIndicating£22.82
Q
LPJ-35SPI
CylindricalJ--1 1/16"35AAIndicating£46.58
M
LPJ-2SP
CylindricalJ--13/16"2ZNonindicating£21.06
R
LPJ-4SP
CylindricalJ--13/16"4ZNonindicating£24.17
N
LPJ-40SP
CylindricalJ--1 1/16"40AANonindicating£35.29
L
LPJ-7SPI
CylindricalJ--13/16"7ZIndicating£25.95
M
LPJ-1SP
CylindricalJ--13/16"1ZNonindicating£24.17
S
LPJ-1-6/10SP
CylindricalJ--13/16"1-6/10ZNonindicating£24.17
M
LPJ-2-8/10SP
CylindricalJ--13/16"2-8/10ZNonindicating£24.17
M
LPJ-3-2/10SP
CylindricalJ--13/16"3-2/10ZNonindicating£25.24
M
LPJ-5-6/10SP
CylindricalJ--13/16"5-6/10-Nonindicating£24.17
M
LPJ-3-1/2SP
CylindricalJ--13/16"3.5ZNonindicating£24.17
M
LPJ-9SP
CylindricalJ--13/16"9ZNonindicating£21.26
Q
LPJ-40SPI
CylindricalJ--1 1/16"40AAIndicating£46.58

LPJ Low-Peak Time Delay Fuses, Dual Element, Class J, With Indictaor

Bussmann LPJ Series Class J fuses are designed to avoid frequent blowing during motor and equipment startups. They feature a compact design for equipment downsizing and optimising space usage. These fuses can handle high interrupting ratings up to 300kA for worry-free installation. They feature low-peak fuses in the series and have consistent 2:1 ampacity ratios for selective coordination of fuses. They have dual elements and offer time-delay characteristics for optimal protection for the connected equipment. These fuses offer current-limiting capabilities to protect downstream components from the thermal and magnetic effects of short-circuit currents. They provide backup protection against motor burnout caused by overload or single-phasing, acting as a secondary protective measure. These dual-element fuses have low resistance for cool operation and improved efficiency.

We are here to help!

Looking for a part not listed here?