Sign In

ASCO VALVES Fuel Gas Solenoid Valve with Test Port

ASCO Numatics fuel gas solenoid valves with test ports are used to regulate the flow of fuel or gas in industrial applications, such as gas-fired power plants, refineries and chemical processes. They ensure safety by quickly shutting off gas flow in emergencies.

Filter
StyleModelAmbient Temp. RangeBtuhCenter Line Pipe Center SizeCoefficient Of VolumeCoil EnclosureElectrical ConnectionsHzNema RatingPrice
A
8214G020
-40 Degrees to 125 Degrees F238,5003-15/32"4.4General Purpose No Junction Box and Watertight1/2" Conduit with 18" Leads50/601, 2, 3, 3S, 4, 4X£235.94
B
JB8214037CSA
-40 Degrees to 125 Degrees F659,000-11General Purpose Junction Box1/2" Conduit with 18" Leads50/601£588.71
C
JB8214280CSA
-40 Degrees to 125 Degrees F2,940,5005.875"55General Purpose Junction Box1/2" Conduit with 18" Leads50/601£783.74
C
JB8214270CSA
-40 Degrees to 125 Degrees F1,887,2005.5"35General Purpose Junction Box1/2" Conduit with 18" Leads50/601£571.23
C
JB8214235CSA
-40 Degrees to 125 Degrees F593,2005.5"11General Purpose Junction Box1/2" Conduit with 18" Leads50/601£436.02
D
8040G023
-40 Degrees to 125 Degrees F512,0003.625"9.5General Purpose No Junction Box and Watertight18" Leads601, 2, 3, 3S, 4, 4X£227.12
C
JB8214250CCSA
-40 Degrees to 125 Degrees F1,132,3005.5"21General Purpose Junction Box1/2" Conduit with 18" Leads50/601£1,062.26
C
JB8214235VICSA
-40 Degrees to 125 Degrees F593,2005.5"11General Purpose Junction Box1/2" Conduit with 18" Leads50/601£609.56
D
8040G022
-40 Degrees to 125 Degrees F291,0003.437"5.4General Purpose No Junction Box and Watertight18" Leads50/601, 2, 3, 3S, 4, 4X£226.53
E
8040H007
-40 Degrees to 125 Degrees F59,0002-5/16"1.1General Purpose No Junction Box and Watertight18" Leads50/601, 2, 3, 3S, 4, 4X£113.40
A
8214G033
-40 Degrees to 125 Degrees F247,5004.031"5.1General Purpose Junction Box1/2" Conduit with 18" Leads50/601, 2, 3, 3S, 4, 4X£381.04
F
JB8214053CSA
-40 Degrees to 125 Degrees F1,179,0003-9/16"21General Purpose Junction Box1/2" Conduit with 18" Leads50/601£644.57
A
8214G030
-40 Degrees to 125 Degrees F247,5003-21/32"5.1General Purpose No Junction Box and Watertight1/2" Conduit with 18" Leads50/601, 2, 3, 3S, 4, 4X£234.04
F
JB8214083CSA
-40 Degrees to 125 Degrees F2,924,5003-13/16"60General Purpose Junction Box1/2" Conduit with 18" Leads50/601£1,091.87
F
JB8214073CSA
-40 Degrees to 125 Degrees F1,615,2503-9/16"35General Purpose Junction Box1/2" Conduit with 18" Leads50/601£903.17
F
JB8214063CSA
-40 Degrees to 125 Degrees F1,538,7503-9/16"32General Purpose Junction Box1/2" Conduit with 18" Leads50/601£733.20
C
JB8214250CSA
-40 Degrees to 125 Degrees F1,132,3005.5"21General Purpose Junction Box1/2" Conduit with 18" Leads50/601£559.05
E
8040H008
-40 Degrees to 125 Degrees F64,4002-5/16"1.2General Purpose No Junction Box and Watertight18" Leads50/601, 2, 3, 3S, 4, 4X£108.96
E
8040H006
-40 Degrees to 125 Degrees F53,7002-5/16"1General Purpose No Junction Box and Watertight18" Leads50/601, 2, 3, 3S, 4, 4X£123.08
C
JB8214260CSA
-40 Degrees to 125 Degrees F1,725,5005.5"32General Purpose Junction Box1/2" Conduit with 18" Leads50/601£521.21
G
SV311A02N6CF5
-40 Degrees to 175 Degrees F64,4002-11/32"1.2General Purpose No Junction Box and Watertight1/2" Conduit50/601, 2, 3, 3S, 4, 4X£250.42
H
8214G023
32 Degrees to 125 Degrees F206,2503.875"4.4General Purpose No Junction Box and Watertight1/2" Conduit with 18" Leads50/601, 2, 3, 3S, 4, 4X£378.36

Working Mechanism

  • They operate based on the principle of electromagnetism. When an electrical current is applied to the coil (solenoid) surrounding the valve, it generates a magnetic field, which attracts a plunger or piston within the valve mechanism.
  • This movement of the plunger or piston opens or closes the valve's main flow passage, allowing or blocking the flow of fuel or gas.
  • The valve returns to its default position (open or closed) when the electrical current is removed, making solenoid valves efficient & reliable for regulating gas flow in response to electrical signals.

Features

  • They feature aluminium construction, ensuring durability and resistance to corrosion.
  • These valves have Class F coil insulation to allow them to operate effectively even in high-temperature environments.
  • They can handle fluids with a maximum temperature of up to 125 degrees F.
  • These valves have a minimal operating pressure differential requirement of 0 psi, ensuring efficient performance in various pressure conditions.
  • They are equipped with NBR seals, enhancing their sealing capabilities.
  • These valves can be configured as normally closed / normally open, providing precise control and flexibility for regulating fluid flow in industrial systems.

Frequently Asked Questions

How do I maintain these ASCO fuel gas solenoid valves?

  • Implement regular inspections to detect signs of wear, corrosion or damage.
  • Check for gas or fluid leaks in both the valve and its connections.
  • Keep the test port clean and free from debris for accurate testing.
  • Examine electrical connections for loose wires or damaged insulation.
  • Verify the solenoid coil's integrity and secure attachment to the valve.
  • Periodically conduct functional tests to ensure proper valve operation.
  • Lubricate moving parts if recommended by the manufacturer.
  • Replace worn-out or damaged components with manufacturer-recommended parts.
  • Ensure the valve operates within its specified environmental conditions.

What safety precautions should I take while using these fuel gas solenoid valves?

  • Ensure proper installation with secure connections, using appropriate tools and fittings.
  • Inspect electrical connections for damage and follow electrical safety codes during installation and maintenance.
  • Operate the valve within specified ambient temperature and environmental conditions to maintain safe performance.
  • Verify compatibility with system pressure and flow requirements, using pressure regulators and relief valves when necessary.
  • Implement routine maintenance as recommended, wearing appropriate personal protective equipment (PPE).
  • Regularly check for gas or fluid leaks around the valve and use leak detection methods for safety.

What valve design does it feature?

This valve is designed as a 2-way / 2-position valve, providing precise control and flexibility for regulating fluid flow in industrial systems.

How does the test port benefit users?

The test port allows users to perform maintenance and diagnostic checks without disrupting the fuel supply, saving time and ensuring system reliability.

What are the factors to consider while choosing these ASCO fuel gas solenoid valves with test ports?

  • Operating environment
  • Flow requirements
  • Pressure and fluid compatibility
  • Electrical specifications
  • Application type
  • Heat output (BtuH)
  • Dimensions and mounting
  • Maintenance and serviceability

We are here to help!

Looking for a part not listed here?