Carling Technologies Panel Mount Circuit Breakers | Raptor Supplies United Kingdom

CARLING TECHNOLOGIES Panel Mount Circuit Breakers

UL-listed and CSA-certified magnetic and thermal circuit breakers ideal for protecting devices from the heat generated due to overcurrent. Provide a temperature-stable performance and hence, unaffected by variations in ambient temperature. Feature a tab / screw / stud terminal connection for easy installation

Filter
CARLING TECHNOLOGIES -

Panel Mounted Circuit Breakers

StyleModelAc Voltage RatingAir @ 120vacAir @ 125vdcAir @ 240vacAir @ 65vdcAir RatingAmpsCircuit Breaker TypePrice (inc. VAT)
ACTB-B-B-07250 VACNot RatedNot Rated1.0kANot Rated1kA7Thermal£3.29
BCA1-B0-34-670-321-D250 VAC1.5kA1.5kA1.5kANot Rated1.5kA70Magnetic£31.70
CCMB-053-27G3N-W-A/05250 VACNot RatedNot Rated0.2KANot Rated2.5kA5Thermal£5.47
CCMB-153-27G3N-W-A/15250 VACNot RatedNot Rated0.2KANot Rated2.5kA15Thermal£3.59
CCMB-053-11C3N-W-A/05250 VACNot RatedNot Rated0.2KANot Rated2.5kA5Thermal£4.57
CCMB-153-11C3N-W-A/15250 VACNot RatedNot Rated0.2KANot Rated2.5kA15Thermal£3.03
DCLB-103-27E3N-W-A/10250 VACNot RatedNot Rated0.2KANot Rated2.5kA10Thermal£3.97
EMU1-B-34-420-1-C21-B-E250 VAC1.5kANot Rated36" x 48"Not Rated-2Magnetic£23.28
FBA2-BO-34-630-111-C250 VACNot RatedNot Rated1.5kA7.5kA-30Magnetic£45.62
BBA1-BO-34-615-111-D250 VACNot RatedNot Rated1.5kA7.5kA-15Magnetic£22.97
FCA2-B0-34-670-321-D250 VAC1.5kA1.5kA1.5kANot Rated1.5kA70Magnetic£62.92
DCLB-403-27E3N-W-A/40250 VACNot RatedNot Rated0.2KANot Rated2.5kA40Thermal£4.91
BBA1-BO-34-630-111-C250 VACNot RatedNot Rated1.5kA7.5kA-30Magnetic£23.12
GBA1-B0-34-625-121-D250 VAC1.5kA1.5kA1.5kANot Rated1.5kA25Magnetic£23.17
HMA1-B-34-450-1-A26-B-E250 VAC1.5kANot Rated36" x 48"Not Rated-5Magnetic£22.89
CCMB-203-27G3N-W-A/20250 VACNot RatedNot Rated0.2KANot Rated2.5kA20Thermal£3.59
ACTB-B-B-05250 VACNot RatedNot Rated1.0kANot Rated1kA5Thermal£3.29
CCMB-103-11C3N-W-A/10250 VACNot RatedNot Rated0.2KANot Rated2.5kA10Thermal£3.09
DCLB-203-27E3N-W-A/20250 VACNot RatedNot Rated0.2KANot Rated2.5kA20Thermal£4.05
DCLB-153-27E3N-W-A/15250 VACNot RatedNot Rated0.2KANot Rated2.5kA15Thermal£3.97
FBA2-BO-34-620-111-D250 VACNot RatedNot Rated1.5kA7.5kA-20Magnetic£45.62
FBA2-BO-34-615-111-D250 VACNot RatedNot Rated1.5kA7.5kA-15Magnetic£44.51
FBA2-BO-34-610-111-D250 VACNot RatedNot Rated1.5kA7.5kA-10Magnetic£44.96
BBA1-BO-34-620-111-D250 VACNot RatedNot Rated1.5kA7.5kA-20Magnetic£23.49
HMA1-B-34-610-1-A26-B-E250 VAC1.5kANot Rated36" x 48"Not Rated-10Magnetic£22.81
CARLING TECHNOLOGIES -

A Series Supplementary Protectors

Carling Technologies A Series hydraulic magnetic supplementary protectors are designed for precision operation in current overload and short circuit scenarios. These panel mounted circuit breakers feature a magnetic trip for instantaneous trip function when an overload is encountered. They have compact frames for better space utilisation in loadcentres and are equipped with a toggle or switch actuator for manual trip operation & fault indication. These UL-listed and CSA-certified breakers are ideal for harsh environment applications requiring additional sealing protection.

StyleModelAmpsDc Voltage RatingPrice (inc. VAT)
AAA1-B0-34-610 -5D1-I1032 VDC£22.26
AAA1-B0-34-615 -5D1-I1532 VDC£22.18
AAA1-B0-34-630 -5D1-I3065 VDC£22.25
AAA1-B0-34-650 -5D1-I5065 VDC£22.26

We are here to help!

Looking for a part not listed here?