StyleModelCfm @ 0.000-in. SpMax. DepthPropeller Dia.Price (inc. VAT)
ASD08-XPF32018-3/8"8£1,079.51
ASD10-XPF62018.38"10£1,147.24
DELHI -

Panel Exhaust Fans

StyleModelCfm @ 0.000-in. SpCfm @ 0.250-in. SpHeightMotor InsulationPropeller Dia.WidthPrice (inc. VAT)
ASD12-XPF1640139017.25"Class B12"17.25"£932.38
BSD18-XPF3200292023.25"Class B18"23.25"£1,129.01
CSD24-XPF5500510029.25"Class 1 C-D, Class 2 F-G24"29.25"£1,185.03
DAYTON -

Hazardous Location Exhaust Fans, Explosion Proof, 20 Inch

Dayton hazardous location exhaust fans are used to remove harmful gases, dust and flammable & explosive vapours. They feature spark-resistant aluminium propellers and 20 inch galvanised frames. These explosion proof fans are equipped with hazardous locati.

StyleModelCfm @ 0.000-in. SpCfm @ 0.125-in. SpCfm @ 0.250-in. SpCfm @ 0.375-in. SpCfm @ 0.500-in. SpFull Load AmpsHeightItemPrice (inc. VAT)
A10E014242920741744134110984.2/2.1-2.024.25"Ring Exhaust Fan£1,262.31
A10E015242920741744134110981.4-1.3/.6524.25"Ring Exhaust Fan£1,375.23
B10E002455742543919354231017.4/3.9-3.724"Panel Exhaust Fan£1,514.24
B10E003455742543919354231011.8-2/124"Panel Exhaust Fan£1,668.51
DAYTON -

Hazardous Location Exhaust Fans, Explosion Proof, 24 Inch

Dayton hazardous location fans remove harmful gases, fumes and flammable vapours from industrial environments. They feature spark-resistant aluminium propellers and 24-inch galvanised frames. These explosion proof fans are equipped with a 60Hz motor (1 or.

StyleModelCfm @ 0.000-in. SpCfm @ 0.125-in. SpCfm @ 0.250-in. SpCfm @ 0.375-in. SpCfm @ 0.500-in. SpFull Load AmpsHeightInside Dia.Price (inc. VAT)
A10E0183837330526371970-1.8-1.6/.828.25"24-1/2"£1,587.03
A10E0163837330526371970-6/3.2-328.25"24-1/2"£1,573.39
B10E004566949464010296319067.4/3.9-3.728"-£1,609.35
B10E006566949464010296319061.8-2/128"-£1,676.30
C10E017566949464010296319067.4/3.9-3.728.25"24-1/2"£1,676.20
C10E019566949464010296319061.8-2/128.25"24-1/2"£1,443.86
D10E0056317585153144729411710.6/5.328"-£1,750.77
D10E007631758515314472941173.2-3/1.528"-£1,858.74
E10E020815375156804595749569.2/5-4.634.25"30-1/2"£1,969.29
DAYTON -

Hazardous Location Direct Drive Exhaust Fans, 12 Inch Blades

Dayton hazardous location exhaust fans ventilate explosive or flammable vapours, dust and gases in warehouses and industries. They have galvanised steel construction with spark-resistant aluminium bladed propellers for corrosion resistance and durability. They are capable of withstanding a maximum ambient temperature of 104 degrees F and feature direct drive motors with class B insulation for directly connecting to the fan through shafts or axles, thereby increasing energy efficiency. They have pre-punched mounting holes for quick installation. Choose from a wide range of these exhaust fans, available in ring exhaust fan and panel exhaust fan variants.

StyleModelCfm @ 0.000-in. SpCfm @ 0.125-in. SpCfm @ 0.250-in. SpCfm @ 0.375-in. SpHeightItemMax. DepthMotor RpmPrice (inc. VAT)
A10E009114799980368216.25"Ring Exhaust Fan13-1/2"1725£1,285.44
B10D99613471262114294716"Panel Exhaust Fan15-3/8"1750£1,307.18
DAYTON -

Exhaust Fan 16 Inch Hazardous Location

Dayton hazardous location 16 inch exhaust fans are designed for ventilating spaces having explosive or flammable vapours, dust and gases. These 16 inch exhaust fans have an explosion-proof, fan-cooled enclosure featuring class B insulation for safe usage. They are equipped with hazardous location ball bearings to reduce rotational friction, allow both horizontal & vertical mounting and are capable of withstanding temperatures up to 104 degrees Fahrenheit. A wide range of these exhaust fans is available in single & three-phase fan motors with 20 or 20.25 inches heights on Raptor Supplies.

StyleModelCfm @ 0.000-in. SpCfm @ 0.125-in. SpCfm @ 0.250-in. SpCfm @ 0.375-in. SpCfm @ 0.500-in. SpFull Load AmpsHeightItemPrice (inc. VAT)
A10E010215319431713136611254.2/2.1-2.020.25"Ring Exhaust Fan£1,252.01
A10E011215319431713136611251.4-1.3/.6520.25"Ring Exhaust Fan£1,196.07
B10D997247622882061176913504.2/2.1-2.020"Panel Exhaust Fan£1,303.31
C10D998247622882061176913501.4-1.3/.6520"Panel Exhaust Fan£1,289.85
DAYTON -

Hazardous Location Direct Drive Exhaust Fans, 18 Inch Blades

Dayton hazardous location exhaust fans ventilate explosive or flammable vapours, dust and gases in warehouses and industries. They have galvanised steel construction with 3, spark-resistant aluminium bladed propellers for corrosion resistance and durability. They are capable of withstanding a maximum ambient temperature of 104 degrees F. These fans feature direct drive motors with class B insulation for directly connecting to the fan through shafts or axles, thereby increasing energy efficiency. They have pre-punched mounting holes for quick installation. Choose from a wide range of these exhaust fans, available in ring exhaust fan and panel exhaust fan variants.

StyleModelCfm @ 0.000-in. SpCfm @ 0.125-in. SpCfm @ 0.250-in. SpCfm @ 0.375-in. SpCfm @ 0.500-in. SpFull Load AmpsHeightItemPrice (inc. VAT)
A10E012237120891756142310884.2/2.1-2.022.25"Ring Exhaust Fan£1,321.44
A10E013237120891756142310881.4-1.3/.6522.25"Ring Exhaust Fan£1,211.87
B10D999316829122612221915996/3.2-322"Panel Exhaust Fan£1,355.21
C10E001316829122612221915991.8-1.6/.822"Panel Exhaust Fan£1,336.89
DAYTON -

Panel Exhaust Fan 12 Inch 115/208-230v

ModelItemPrice (inc. VAT)
32ZN53AG3ECN£1,061.57
DAYTON -

Ring Exhaust Fan 12 Inch 115/208-230v

ModelItemPrice (inc. VAT)
32ZN54AG3ECP£1,162.10

Hazardous Location Exhaust Fans

Hazardous location exhaust fans ventilate explosive or flammable vapours, dust and gases in warehouses and industries. Raptor Supplies offers hazardous location exhaust fans from brands like Delhi Blowers, Dayton and Canarm. They feature aluminium propellers and an explosion-proof motor for ensuring corrosion resistance and durability. Choose from a wide range of these hazardous location exhaust fans with propellor diameters ranging from 8 to 30 inches.

We are here to help!