Flow Switches

22 - 39 of 39 Items (210 Products) Filter

Flow switches detect fluid flow in hydraulic systems and prevent leaks. They are used in pumps in the water treatment, oil & gas and chemical industries.

TACO -

Flow Switch 3.5 - 600 Spdt

StyleModelMedia Temp. RangeMax. Ambient Temp.Enclosure RatingHpHousing MaterialSwitch TypeConnection SizeConnection TypePrice (inc. VAT)
AIFSH1BR-1+32°F to +250°F176°FNEMA 11/2 hp to 1 hpBrassSPDT1"NPT£287.19
BIFS02BF-1+32°F to +250°F176°FNEMA 11/8 hp to 1/4 hpBrassSPDT1"NPT£378.27
CIFS01BR-1+32°F to +250°F176°FNEMA 11/8 hp to 1/4 hpBrassSPDT1"NPT£326.60
DIFSH2BF-1+32°F to +250°F176°FNEMA 11/2 hp to 1 hpBrassSPDT1"NPT£378.68
EIFSW2BF-1+32°F to +250°F176°FNEMA 41/8 hp to 1/4 hpBrassSPDT1"NPT£441.86
FIFSW2BR-1+32°F to +250°F176°FNEMA 41/8 hp to 1/4 hpBrassSPDT1"NPT£310.67
GIFS01BF-1+32°F to +250°F176°FNEMA 11/8 hp to 1/4 hpBrassSPDT1"NPT£220.74
HIFSH1BF-1+32°F to +250°F176°FNEMA 11/2 hp to 1 hpBrassSPDT1"NPT£272.60
IIFSWSBR-1-20°F to +250°F151°FNEMA 41/3 hpBrassSPDT1"NPT£336.95
JIFSWSBF-1-20°F to +250°F151°FNEMA 41/3 hpBrassSPDT1"NPT£293.74
GEMS SENSORS -

Flow Switch 40 Cm/sec

StyleModelConnection SizeMin. Flow RateMax. Flow RateMin. Ambient Temp.Overall WidthHousing MaterialSwitch TypeSwitch PositionPrice (inc. VAT)
A230500-4-51 1/2"1 GPM5 GPM-14°2.3"Stainless SteelSPSTNormally Open£726.46
A230500-3-401"1 GPM3 GPM-14°1 1/2"Stainless SteelSPSTNormally Open£693.19
A230500-3-51"0 GPM0.64 GPM-14°F1 1/2"Stainless SteelSPSTNormally Open£726.46
A230500-2-53/4"0 GPM0.35 GPM-14°1 1/2"Stainless SteelSPSTNormally Open£693.19
A230500-2-403/4"1 GPM1.9 GPM-14°-Stainless SteelSPSTNormally Open£660.46
GEMS SENSORS -

Flow Switch 60 Cm/sec

StyleModelConnection SizeMax. Flow RateMin. Ambient Temp.Overall WidthHousing MaterialSwitch TypeSwitch PositionConnection TypePrice (inc. VAT)
A230500-3-601"4.34 GPM-14°F1 1/2"Stainless SteelSPSTNormally OpenFNPT£693.19
A230500-1-601/2"1.34 GPM-14°1.1"Stainless SteelSPSTNormally OpenFNPT£693.19
A230500-2-603/4"2.79 GPM-14°1 1/2"Stainless SteelSPSTNormally OpenFNPT£726.46
GEMS SENSORS -

FS-150Series Flow Switch

StyleModelSwitch PositionMax. Flow RateMax. PressureHousing MaterialSwitch TypeConnection SizeConnection TypeSwitch EnclosurePrice (inc. VAT)
AFS-150 NC 1.0GPMNormally Closed1 GPM150 psi, 200 psiPolypropyleneSPST1/2"NPTPolypropylene£176.69
AFS-150 NC 0.5GPMNormally Closed-150 psi, 200 psiPolypropyleneSPST1/2"NPTPolypropylene£190.82
AFS-150 NO 0.5GPMNormally Open0.5 GPM150 psi, 200 psiPolypropyleneSPST1/2"NPTPolypropylene£190.82
AFS-150 NO 2.0GPMNormally Open2 GPM150 psi, 200 psiPolypropyleneSPST1/2"NPTPolypropylene£181.12
AFS-150 NO 1.0GPMNormally Open1 GPM200 psiPolypropyleneSPST1/2"NPTPolypropylene£184.08
AFS-150 NO 3.0GPMNormally Open3 GPM150 psi, 200 psiPolypropyleneSPST1/2"NPTPolypropylene£190.82
GEMS SENSORS -

FS-4 Series Flow Switch

StyleModelSwitch TypeMin. Flow RateMax. Flow RateHousing MaterialConnection SizeConnection TypeMin. Ambient Temp.Max. PressurePrice (inc. VAT)
AFS-4 122352SPDT0 GPM0.1 GPMPolyphenylene Sulfide9/16"UNF0°F250 psi£204.18
AFS-4 122355SPDT1 GPM0.75 GPMPolyphenylene Sulfide9/16"UNF0°F250 psi£187.57
AFS-4 122356SPDT0 GPM0.5 GPMPolyphenylene Sulfide9/16"UNF0°F250 psi£195.75
AFS-4 122353SPDT1 GPM0.25 GPMPolyphenylene Sulfide9/16"UNF0°F250 psi£220.51
AFS-4 122354SPST0 GPM0.5 GPMPolyphenylene Sulfide9/16"UNF0°F250 psi£210.39
StyleModelMax. Flow RateMedia Temp. RangeSwitch TypeConnection SizeConnection TypeMin. Flow RateMin. Ambient Temp.Max. PressurePrice (inc. VAT)
AFS-926 269420.013 GPM-20°F to +225°FSPDT1/4"FNPT0 GPM-20°F1000 psi£482.97
AFS-926 269380.013 GPM-20°F to +225°FSPDT1/4"FNPT0 GPM-20°F1000 psi£508.90
AFS-926 269510.025 GPM-20°F to +300°FSPDT1/4"FNPT0 GPM-20°F1000 psi£827.08
AFS-926 269390.045 GPM-20°F to +225°FSPDT1/4"FNPT0 GPM-20°F1000 psi£482.97
AFS-926 269410.065 GPM-20°F to +225°FSPDT1/4"FNPT0 GPM-20°F1000 psi£508.90
AFS-926 269560.075 GPM-20°F to +300°FSPDT1/4"FNPT0 GPM-20°F1000 psi£789.20
AFS-926 269521 GPM-20°F to +225°FSPDT1/4"FNPT0 GPM-20°F1000 psi£827.08
StyleModelSwitch PositionMin. Flow RateMax. Flow RateHousing MaterialSwitch TypeConnection SizeConnection TypeMin. Ambient Temp.Price (inc. VAT)
AFS-927 70826Normally Closed0 GPM0.1 GPMBrassSPST1/4"FNPT-20°F£194.92
AFS-927 70828Normally Closed0 GPM0.5 GPMBrassSPST1/4"FNPT-20°F£172.74
AFS-927 70831Normally Closed1 GPM1.5 GPMBrassSPST1/4"FNPT-20°F£164.83
AFS-927 70827Normally Closed0 GPM0.25 GPMBrassSPST1/4"FNPT-20°F£193.91
AFS-927 70830Normally Closed0 GPM1 GPMBrassSPST1/4"FNPT-20°F£203.23
AFS-927 70829Normally Closed0 GPM0.75 GPMBrassSPST1/4"FNPT-20°F£193.91
AFS-927 70822Normally Open0 GPM0.5 GPMBrassSPST1/4"FNPT-20°F£214.15
AFS-927 70823Normally Open0 GPM0.75 GPMBrassSPST1/4"FNPT-20°F£186.78
AFS-927 70821Normally Open0 GPM0.25 GPMBrassSPST1/4"FNPT-20°F£204.42
AFS-927 70825Normally Open1 GPM1.5 GPMBrassSPST1/4"FNPT-20°F£204.42
AFS-927 70820Normally Open0 GPM0.1 GPMBrassSPST1/4"FNPT-20°F£203.23
DAYTON -

Flow Protector Booster Pump 230 V

ModelItemPrice (inc. VAT)
1DGZ8AA9HXM£643.90
SPEAKMAN -

Flow Switch Retro Kit

ModelItemPrice (inc. VAT)
RPG76-0043CE2DRB£2,000.64
JOHNSON CONTROLS -

Air Flow Switch, 2-1/8 Inch x 6-7/8 Inch Paddle Size, 16.0/8.0

ModelItemPrice (inc. VAT)
F262KDH-01CCR6AJW£322.05
MCDONNELL & MILLER -

Air Flow Switch

ModelItemPrice (inc. VAT)
AF1-SCH9NXF£819.63
DWYER INSTRUMENTS -

Flow Switch Brass

ModelItemPrice (inc. VAT)
V6EPB-B-S-LFCP4LMW£645.55
DWYER INSTRUMENTS -

Thermal Dispersion Flow Switch

ModelItemPrice (inc. VAT)
TDS112CP4LMX£882.53
DWYER INSTRUMENTS -

Level Switch Brass Body Spdt

ModelItemPrice (inc. VAT)
L6EPB-B-S-3-BCP4LMY£690.57
HONEYWELL -

Flow Switch Kit, Single Pack

ModelItemPrice (inc. VAT)
50053268-018/UBN9YWH£221.32
See Details
HONEYWELL -

Flow Switch, 1-1/4 Inch NPT Size

ModelItemPrice (inc. VAT)
FS7-4/UBP3GTR£671.39
See Details
HONEYWELL -

Air Flow Switch

ModelItemPrice (inc. VAT)
4074ETH/UBP2AFQ£118.50
See Details
HONEYWELL -

Flow Switch, 1 Inch NPT Size

ModelItemPrice (inc. VAT)
FS4-3/UBP3GTN£287.64
See Details
12

Flow Switches

Flow switches are primarily designed to monitor the air, steam or liquid flow and send signals to the pump for automatic ON / OFF switching with the rise and fall of water level; ideal for regulating water cooling equipment and water treatment or hydronic heating systems. Raptor Supplies offers a wide range of these liquid flow switches from brands like Bradley, Dwyer Instruments, Mcdonnell & Miller, Dayton, Johnson Controls, Gems Sensors and Taco. Gems Sensors flow switches uses 100-micron filtration technology and are less susceptible to clogging than other high-pressure inline flow switches. These units come equipped with one-piece magnetic composite piston which actuates the sealed reed switch when displaced by the pressure difference in fluid flow, thereby activating remote alarms or indicators. They are available in brass, polypropylene and stainless steel construction with a maximum pressure rating and flow rate of 1500 psi and 2 GPM, respectively. Taco industrial flow switches feature flow sensitivity adjustment mechanism for setting a wide adjustment range to start or stop an electronically operated device when flow / no-flow condition occurs. These low-flow switches come with a highly malleable EPDM seal providing anti-hardening, cracking and leakage properties and improving the performance in high-pressure applications such as chillers, boilers, heating systems and water systems. They are available in NEMA 1 and NEMA 4 rated enclosures providing protection against the ingress of foreign contaminants and are ideal for use with 1 - 8 inch (outer diameter) pipe sizes.

Frequently Asked Questions

How can I maintain the accuracy of my flow switch over time?

  • Regularly clean the flow switch and inspect it for any signs of damage, corrosion or debris buildup.
  • Verify that the flow switch is properly aligned within the flow path to ensure accurate measurements.
  • Periodically calibrate the flow switch to verify its accuracy.
  • Take into account the properties of the fluid being monitored, such as viscosity or density, as these factors can impact the accuracy of the flow switch.
  • Be aware of the ambient conditions surrounding the flow switch. Consider protective enclosures for use in harsh environments.
  • Maintain a record of the flow switch's calibration dates, maintenance activities and any observed issues.

What is the difference between a flow switch and a pressure switch?

A flow switch measures the flow rate of media flowing through a process line, whereas a pressure switch measures the pressure within a process line, pipe or vessel.

How do I select the right flow switch for my application?

Consider factors like the type of fluid, flow rate, operating conditions (temperature or pressure) and pipe size.

Do these flow switches require regular maintenance?

These flow switches require minimal maintenance. However, periodic inspection and cleaning are necessary to ensure proper functioning.

Can I use these flow switches for both liquids and gases?

Yes, these flow switches can be used to detect the flow of both liquids and gases.

We are here to help!

Looking for a part not listed here?