StyleModelTurn On LevelHpPump TypeTank CapacityMax. Flow Rate @ 5 Ft.Max. Flow Rate @ 10 Ft.Max. Flow Rate @ 15 Ft.Max. Flow Rate @ 20 Ft.Price (inc. VAT)
AHDP-AI-H1-230-601 1/4"13/1000 hpLow Profile1 gal.9.5 GPH9 GPH8.5 GPH8 GPH£1,602.44
AHDP-A1-H1-115-601 3/4"13/1000 hpLow Profile1 gal.9.5 GPH9 GPH8.5 GPH8 GPH£1,535.61
LITTLE GIANT PUMPS -

Vcl-45 Series Condensate Pumps

StyleModelPump TypeMax. Flow Rate @ 15 Ft.FrequencyHousing MaterialWattageFlow Rate @ 5 Ft.Flow Rate @ 1 Ft.HpPrice (inc. VAT)
A553240Condensate Removal Pump6.3 GPM60 HzPlastic185 W7.3 GPM7.5 GPM1/5 hp£465.96
A553245Standard380 GPH50/60 HzABS250 W440 GPH450 GPH1/5 hp£770.45
StyleModelMax. Flow Rate @ 15 Ft.Flow Rate @ 10 Ft.Flow Rate @ 5 Ft.Flow RateNoise LevelCooling CapacityPump TypeTank CapacityPrice (inc. VAT)
AHAR-82.1 GPH2.4 GPH2.6 GPH3.17 GPH19 dBA30000 btuMini Split1.18 oz.£68.42
AHAR-153.7 GPH4.2 GPH4.5 GPH5.28 GPH21 dBA45000 btuMini Split1.18 oz.£87.75
StyleModelTank CapacityFlow RateNoise LevelCooling CapacityPump TypeFrequencyWattagePump HeadPrice (inc. VAT)
AHAD-81.18 fl. oz.3.17 GPH19 dBA30000 btuMini Split50/60 Hz3 W26 ft.£72.59
AHAD-159 gal.5.28 GPH21 dBA45000 btu-50/60 Hz3 W26 ft.£85.64
StyleModelHpWattagePump TypeTank CapacityMax. Flow Rate @ 15 Ft.Intake Connection StyleDischarge Connection StyleCord LengthPrice (inc. VAT)
APABX-1151/20 hp128 WStandard1 gal.0.9 GPMOpenBarbed6 ft.£358.78
APABX-2301/25 hp125 WStandard1 gal.0.9 GPMOpenBarbed6 ft.£358.78
StyleModelTypeHpTank CapacityPump TypeTank MaterialReservoir CapacityRpmReservoir MaterialPrice (inc. VAT)
AA2SA-X115With Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£547.69
AA2SA-X230With Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£548.40
AA2SA-X115 W/ALT INLETWith Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£557.63
AA2SA-X230 W/ALT INLETWith Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£558.34
AA2SA-115 W/ALT INLETWithout Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£562.46
AA2SA-230 W/ALT INLETWithout Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£563.16
AA2SA-115Without Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£551.36
AA2SA-230Without Auxiliary Switch1/10 hp1 gal.CondensateDie Cast Aluminum1 gal.3000 RPMCast Aluminum£553.23
StyleModelHpTank CapacityPump TypeTypeMax. Flow Rate @ 15 Ft.Tank MaterialReservoir CapacityRpmPrice (inc. VAT)
AL4-115/2301/2 hp2 gal.-Without Auxiliary Switch-Die Cast Aluminum2 gal.3450 RPM£1,249.02
AL4-115/230 W/ALT INLET1/2 hp2 gal.CondensateWithout Auxiliary Switch-Die Cast Aluminum2 gal.3450 RPM£1,352.07
AL4X-115/230 W/ALT INLET1/10 hp1 gal.Plenum RatedWith Auxiliary Switch4.7 GPMDie Cast Aluminum2 gal.3450 RPM£1,259.69
HARTELL -

HAT Series Reservoir Condensate Pumps

StyleModelTank CapacityWattageFlow RatePump HeadPower ConsumptionNoise LevelPump TypeMax. Flow Rate @ 15 Ft.Price (inc. VAT)
AHAT-2LP0.26 gal.15 W36 GPH13 ft.15 W48 dBAReservoir Condensate Pump-£60.98
BHAT-1DC0.26 gal.60 W56 GPH13 ft.60 W26 dBA--£66.77
BHAT-2DC0.26 gal.60 W56 GPH13 ft.60 W26 dBA--£66.77
AHAT-1LP0.26 gal.15 W36 GPH13 ft.15 W48 dBA--£60.98
CHAT-1LT0.47 gal.28 W42.2 GPH15 ft.28 W28 dBA-42.2 GPH£59.25
AHAT-2LT0.47 gal.28 W42.2 GPH15 ft.28 W28 dBA--£56.09
StyleModelTypeHpTank CapacityPump TypeTank MaterialReservoir CapacityRpmReservoir MaterialPrice (inc. VAT)
AA2-X230With Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£473.18
AA2-X115With Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£472.79
AA2-230Without Auxiliary Switch1/10 hp1 gal.General PurposeDie Cast Aluminum1 gal.3000 RPMCast Aluminum£460.97
AA2-115Without Auxiliary Switch1/10 hp1 gal.-Die Cast Aluminum1 gal.3000 RPMCast Aluminum£460.58
StyleModelTank MaterialTypeFlow Rate @ 20 Ft.HpTank CapacityMax. Flow Rate @ 15 Ft.Pump TypeIntake Connection StylePrice (inc. VAT)
AAL2-230Die Cast AluminumWithout Auxiliary Switch51 GPH1/10 hp2 gal.1.7 GPM--£724.23
AAL2-115Die Cast AluminumWithout Auxiliary Switch0.9 GPM1/10 hp2 gal.1.7 GPM--£706.66
AAL2-X115Die Cast AluminumWith Auxiliary Switch0.9 GPM1/10 hp2 gal.1.7 GPMStandardOpen£849.10
AAL2-X230Die Cast AluminumWith Auxiliary Switch0.9 GPM1/10 hp2 gal.1.7 GPMStandardOpen£823.07
LITTLE GIANT PUMPS -

VCMA-15 Series Condensate Removal Pump

StyleModelPump TypeMin. Temp.HpTank CapacityMax. Flow Rate @ 15 Ft.Turn On LevelFrequencyCord LengthPrice (inc. VAT)
A554411Condensate Removal Pump140°F1/50 hp0.5 gal.--60 Hz6 ft.-
RFQ
B554401Condensate Removal Pump75°F1/50 hp0.5 gal.--60 Hz6 ft.£47.53
A554415Standard-1/50 hp-0 GPM2 1/2"60 Hz6 ft.£94.88
LITTLE GIANT PUMPS -

VCMA-20 Series Condensate Removal Pump

StyleModelFrequencyMax. PressureHpPump TypeTank CapacityMax. Flow Rate @ 5 Ft.Max. Flow Rate @ 10 Ft.Max. Flow Rate @ 15 Ft.Price (inc. VAT)
A55446150/60 Hz7.4 psi1/30 hpStandard0.5 gal.1.2 GPM0.8 GPM0.4 GPM£131.14
B55443560 Hz8.7 psi1/30 hpStandard0.5 gal.1.2 GPM0.8 GPM0.4 GPM£118.83
LITTLE GIANT PUMPS -

Condensate Pump

StyleModelHpPump TypeTank CapacityTurn On LevelMax. Flow Rate @ 5 Ft.Max. Flow Rate @ 10 Ft.Max. Flow Rate @ 15 Ft.Max. Flow Rate @ 20 Ft.Price (inc. VAT)
A5544251/3 hpStandard0.5 gal.2 1/2"----£112.35
B5513201/12 hpIn Pan1 gal.4 1/2"----£506.92
C5532111/18 hpStandard1 gal.3 1/2"----£185.47
D5532011/18 hpStandard1 gal.3 1/2"4.2 GPM3.3 GPM2.5 GPM1.7 GPM£220.29
E5545421/30 hpStandard0.333 gal.1 3/5"1.3 GPM1 GPM0.7 GPM0.2 GPM£103.55
F5535071/50 hpMini Split0.01 gal.4/9"--1.3 GPH--
RFQ
A5544051/50 hpStandard0.5 gal.1 8/9"0.8 GPM0.4 GPM0 GPM-£122.43
G5531011/50 hpStandard1 gal.3 1/2"----£274.55
H5505321/150 hpIn Pan0 gal.1 3/4"2.4 GPM0 GPM--£158.51
I5505211/150 hpIn Pan0 gal.1 3/4"2.4 GPM0 GPM--£252.19
LITTLE GIANT PUMPS -

Condensate Removal Pump, Plenum Rated/Std, 1 Gal Tank, 1/8 Hp, 208-230VAC

ModelItemPrice (inc. VAT)
553130102CR9QGT£770.67
SUPCO -

Condensate Removal Pump

ModelItemPrice (inc. VAT)
SPCP115CU4VRP£57.22
LITTLE GIANT PUMPS -

Low Profile Condensate Pump, 115 V, 60 Hz

ModelItemPrice (inc. VAT)
554201101CV8PLK£94.70
BECKETT -

BK171TUL Medium Condensate Pump w/Safety Switch and tubing, 115V, 17 Foot Max Lift

ModelItemPrice (inc. VAT)
BK171TULCY7GCJ-
RFQ
BECKETT -

Pump-230V Condensate

ModelItemPrice (inc. VAT)
CB502ULCY7GFW-
RFQ
BECKETT -

Pump-230V Condensate Low Pro

ModelItemPrice (inc. VAT)
CL202ULCY7GJF-
RFQ
BECKETT -

Pump-115V Condensate

ModelItemPrice (inc. VAT)
CB251ULCY7GJN-
RFQ
BECKETT -

Pump-230V Condensate 212 degree

ModelItemPrice (inc. VAT)
CB502ULHTSCY7GJQ-
RFQ

Condensate Pumps

Condensate pumps are used for collecting and removing condensate water from refrigeration, HVAC, steam and condensing boiler furnace systems. Raptor Supplies offers a wide range of condensate pumps from Little Giant, Dayton and Marvel. These pumps are electrically powered and run intermittently. Little Giant condensate pumps are used in high-efficiency gas furnaces, air conditioning units and condensing boilers where gravity drainage is not possible. These pumps have floats made of ABS plastic, polypropylene and polystyrene ensuring low friction, high tensile strength and excellent shock resistance. They can handle pressure up to 26 psi and can be operated at temperatures up to 140 degrees F. Marvel condensate pumps are designed for use with clear ice makers. They feature sealed reservoirs to prevent flooding & leaks, and provide a reservoir capacity of 38.9 oz. These UL and cUL listed pumps deliver an output of 1035 watts and can be operated at temperaturess up to 110 degrees F. These condensate pumps have current ratings ranging between 0.1 and 9 A.

Frequently Asked Questions

What is the significance of high-level alarms in these condensate pumps?

High-level alarms are installed in a condensate tank that signals excessive build-up of condensate while protecting against leaks and overflows that may cause severe damage.

How do you install a condensate pump in a boiler?

  • Ensure the pump is free from packaging and debris, with clear venting slots.
  • Turn off the power at the fuse box.
  • Connect the power cord to the specified voltage from a constant power source.
  • Wire any safety switch according to the pump's specifications.
  • Securely mount the pump close to the air conditioning unit, below the coil drain, ensuring it is level.
  • Use screws to attach the pump to the wall, ensuring it won't splash or interfere with operation.
  • Use flexible tubing as the drain pipe, ensuring gravity assists in draining.
  • Consider installing a check valve on the discharge line to prevent backflow.
  • Turn the power back on and run the air conditioning unit to test the pump.
  • Ensure proper functioning of electrical components and check for leaks in the piping.

What is the recommended capacity for condensate pumps?

The typical Gallons Per Hour (GPH) capacity of condensate pumps ranges from 2 to 3 times the condensing rate of water per hour. For larger tanks, a capacity of 1.5 to 2 times the condensing rate may be sufficient.

How do I choose the right condensate removal pump for my applications?

Consider factors such as the amount of condensate produced, the size of the HVAC system, the installation space available and specific requirements or features you may have, such as alarm or automatic shutoff systems.

We are here to help!