Dayton axial fans are commonly used for cooling in compact spaces including cabinets, electronic instruments, copy machines and computers. For wear reduction & damage protection, these fans monitor temperature by discharging hot air and allowing cool air inside the enclosure. Dayton axial fans are generally placed near heat generating power sources & motors, allow both horizontal & vertical mounting and are equipped with ball bearings for reducing rotational friction & protecting the enclosure from dust particles. Raptor Supplies is an authorised Dayton distributor hosting a huge selection of these axial fans with auto & impedance thermal protection and speeds ranging from 1400 to 3200 rpm.

Filter

Dayton axial fans are commonly used for cooling in compact spaces, including cabinets, electronic instruments, copy machines and computers.
DAYTON -

Skeleton Axial Fan

Dayton skeleton axial fans are designed for use in dry locations to cool a device or equipment such as copy machines, electronic instrumentation, cabinets or computers. These fans come with mounting arms, in place of a full housing, thereby making them suitable for installation in tight spaces. All these units feature an aluminium alloy frame with polycarbonate fan blades driven by shaded pole motors to deliver speeds and airflow rates up to 3000 RPM and 110 CFM, respectively. They are capable of withstanding a maximum temperature of 70 degrees C and are available in ball and sleeve type bearing variants.

StyleModelVoltageWattsAmpsBearingsCFM @ 0.000-In. SPdBAFan RPMMounting PositionPrice (inc. VAT)
A2VUW4115 VAC150.18Ball87383000Vertical or Horizontal£11.17
B2VUW5115 VAC140.16Sleeve82362900Horizontal£10.56
C2VUW6115 VAC140.16Ball83402900Vertical or Horizontal£33.63
D2VUW7230 VAC140.09Sleeve82373000Horizontal£28.00
E2VUW8230 VAC140.09Ball78423000Vertical or Horizontal£33.63
D2VUX1230 VAC130.08Ball82372900Vertical or Horizontal£13.13
DAYTON -

Axial Fans

StyleModelDepthSound LevelAir FlowRPMShapeAmpsVoltageWattsPrice (inc. VAT)
A55VD30--------£32.22
B55VD27--------£17.43
C55VD32--------£64.52
D55VD28--------£32.94
E55VD262"59/63 dB197/232 cfm2900/3300Oblong0.23/0.29A120V AC27/32W£70.68
F55VD352"59/62 dB196/229 cfm2900/3300Oblong0.11/0.14A230V AC24/30W£71.23
G55VD333 1/2"50/54 dB539/461 cfm1400/1700 RPMRound0.37/0.38A120V AC42/43W£104.14
H55VD363 1/2"51/54 dB452/527 cfm1400/1700 RPMRound0.37/0.38A120V AC42/43W£104.14
I55VD313 1/2"51/54 dB454/537 cfm1400/1700 RPMRound0.18/0.19A230V AC38/40W£104.14
DAYTON -

Square Axial Fan

Dayton square axial fans are designed for use in dry locations to cool equipment within an enclosure. These equipment-cooling fans come with a square housing which can be mounted over a round or square cutout for easy installation. They are further provided with mounting holes, at each corner, so that they can be secured to a wall or panel. Choose from a range of these axial fans available in sleeve, ball and zero friction air bearing options.

StyleModelMounting PositionFan RPMAmpsBlade MaterialCFM @ 0.000-In. SPdBADepthElectrical ConnectionsPrice (inc. VAT)
A2RTD1Horizontal31000.25Polybutylene115491.5"Terminals£44.11
B2RTD9Horizontal31000.12Polybutylene115491.5"Terminals£30.50
C4WT49Vertical17500.12Polybutylene Terephthalate5533.51.5"Terminals£23.34
D4WT48Vertical20000.13Polybutylene Terephthalate70361.5"Terminals£23.59
E4WT46Vertical31000.24Polybutylene Terephthalate115491.5"Terminals£43.80
F4WT40Vertical27500.13Polybutylene Terephthalate30351.5"12" Leads£30.81
G4WT33Vertical29000.11Polybutylene Terephthalate105481.5"Terminals£19.40
H6KD74Vertical or Horizontal31000.26Polybutylene Terephthalate138421.5"12" Leads£44.42
I6KD73Vertical or Horizontal26000.06Polybutylene Terephthalate48331"12" Leads£33.13
J6KD70Vertical or Horizontal31000.5Polybutylene Terephthalate108421.5"12" Leads£37.45
K6KD69Vertical or Horizontal26000.13Polybutylene Terephthalate48331"12" Leads£34.93
L3VU66Vertical or Horizontal32500.27Polybutylene Terephthalate355663.5"Terminals£184.51
M3VU65Vertical or Horizontal30000.18Polybutylene Terephthalate105481.5"Terminals£66.67
N3LE74Vertical or Horizontal30500.11Polybutylene Terephthalate107501.5"Terminals£49.00
O2RTK6Vertical or Horizontal27500.25Polybutylene124471.5"Terminals£31.70
P2RTJ7Vertical or Horizontal38000.57Polybutylene170511.5"12" Leads£67.06
Q2RTJ3Vertical or Horizontal49000.51Polybutylene120.257.61.5"12" Leads£33.02
R2RTH8Vertical or Horizontal49000.14Polybutylene59.551.61.5"12" Leads£31.52
S2RTH6Vertical or Horizontal57000.4Polybutylene84.155.21.5"12" Leads£69.09
T2RTH1Vertical or Horizontal61000.13Polybutylene31.5411"12" Leads£25.39
U2RTF9Vertical or Horizontal61000.27Polybutylene40411"12" Leads£25.39
V2RTF2Vertical or Horizontal43000.16Polybutylene11263/8"12" Leads£7.18
W2RTE8Vertical or Horizontal33000.12Polybutylene41331"12" Leads£29.23
X2RTE4Vertical or Horizontal42000.17Polybutylene18311"12" Leads£22.72
Y2RTE1Vertical or Horizontal31500.12Polybutylene117501.5"Terminals£51.51
DAYTON -

Oblong Compact Axial Fans

StyleModelPrice (inc. VAT)
A786EW7£111.38
B786EW9£112.81
C786EW8£116.97
DAYTON -

Round Compact Axial Fans

StyleModelPrice (inc. VAT)
A786EW6£229.25
B786EW5£219.71
DAYTON -

Standard Round Axial Fans

Dayton round axial fans are designed to supply fresh air and to take out the air from return air trenches, rotary filters. They feature circular housing that fits a round cutout for cooling equipment within an enclosure. These equipment-cooling fans need negligible space for installation and are used to replace round fans in existing installations. Choose from a range of these round axial fans, available in PSC and shaded pole motor types.

StyleModelFan RPMThermal ProtectionAmpsMotor TypeCFM @ 0.000-In. SPWattsdBADepthPrice (inc. VAT)
A2RTK92900Auto1.1PSC870120703.5"£237.52
B2RTK72950Impedance0.48Shaded Pole20036552"£77.23
DAYTON -

Square Axial Blower

Dayton square axial fans feature a square-shaped housing which spans over a round or a square cutout for accommodating cooling equipment within an enclosure. They are provided with mounting holes, at each corner, which secure them to a wall or panel. They are available in shaded and DC motor variants on Raptor Supplies.

StyleModelVoltageHeightAmpsCFM @ 0.000-In. SPdBADepthElectrical ConnectionsFan RPMPrice (inc. VAT)
A5JME412 VDC4.75"0.8235.953.81.25"12" Leads2500£45.02
B5JME524 VDC4.75"0.3835.953.81.25"12" Leads2500£50.02
B5JME648 VDC4.75"0.1231.449.61.25"12" Leads2100£21.71
C2RTD3230 VAC4.75"0.1122501.5"Terminals2900£21.66
D2RTK4230 VAC5"0.078.5332.375"12" Leads1400£56.01
DAYTON -

Square Compact Axial Fans

StyleModelItemPrice (inc. VAT)
A55VD25Axial Fan£24.22
B55VD29Axial Fan£32.93
C786EU8Fan Kit£67.54
D786EV6Fan Kit£70.87
E786EV8Fan Kit£70.65
F786EV0Fan Kit£68.31
G786EV7Fan Kit£74.14
H786EW0Fan Kit£70.42
I786EW1Fan Kit£69.25
J786EU7Fan Kit£70.65
K786EV9Fan Kit£67.35
L786EV3Fan Kit£73.90
M786EV2Fan Kit£71.04
N786EW2Fan Kit£67.86
O786EV5Fan Kit£69.18
P786EU9Fan Kit£73.94
Q786EU6Fan Kit£70.01
R786EW4Fan Kit£68.76
S786EV4Fan Kit£72.38
T786EW3Fan Kit£65.84
U786EV1Fan Kit£70.65
DAYTON -

Axial Fan 24vdc 12in.leads 3100 Rpm

ModelItemPrice (inc. VAT)
31CC85AG2AUP£36.76

Standards and Approvals

  • UL

Frequently Asked Questions

How do axial fans operate?

Axial fans are a kind of compressor that improves airflow pressure as it passes through. The fan blades operate by venting air to move parallel to the shaft, which the blades rotate around.

Where are axial fans generally used?

Axial fans are commonly employed to cool both large and small spaces. They can be used in HVAC operations in heat exchange units, AC condensers or for spot cooling in industrial systems.

What is the difference between centrifugal and axial fans?

Centrifugal fans vent air at right angles to the intake of the fan and revolve the air outwards to the outlet by deflection and centrifugal force. Axial fans move the extracted air parallel to the shaft about which the blades rotate.

We are here to help!

Looking for a part not listed here?